Background: To analyze contrast free adrenal vein sampling (AVS) for differentiating unilateral from bilateral disease in patients diagnosed with hypertension due to primary aldosteronism (PA).

Methods: Consecutive patients with PA and subsequent contrast medium free AVS between April 2015 and March 2020 were retrospectively included. Cross-sectional imaging (CSI), AVS and clinical data were analyzed regarding diagnostic performance. In addition, patients with lateralisation receiving adrenalectomy were compared to a control group treated with mineralocorticoid antagonists.

Results: In total 186 patients with AVS were included. The success rate for bilateral catheterization was 88% (median effective dose 2.8 mSv). CSI had an accuracy of 60% (CI: 0.52-0.67) in the detection of lateralization compared to AVS. Patients with bilateral adrenal hyperplasia and those with aldosterone-producing adenoma did not differ in systolic blood pressure (sBP) (p = 0.63) or number of antihypertensive drugs (NAD) (p = 0.11). After adrenalectomy, 28 patients were cured (51%; sBP ≤130 mmHg, NAD = 0), 18 were improved (33%; decrease of sBP ≥20 mmHg and NAD), and 8 were unchanged (15%). Serum renin increased significantly after treatment (p < 0.01).

Conclusion: Contrast medium free AVS is a reliable procedure in the diagnostic management of patients with PA with high technical success rate. The accordance between CSI and results from AVS was only moderate indicating the central role of AVS in the diagnostic work-up of patients with PA. Patients with predominant disease diagnosed with AVS had a high cure rate and/or significant improvement after adrenalectomy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinimag.2023.04.002DOI Listing

Publication Analysis

Top Keywords

contrast medium
8
medium free
8
adrenal vein
8
vein sampling
8
primary aldosteronism
8
patients
6
avs
5
free selective
4
selective adrenal
4
sampling management
4

Similar Publications

Background: Hematoxylin and eosin (H&E) staining is widely considered to be the gold-standard diagnostic tool for histopathology evaluation. However, the fatty nature of some tissue types, such as breast tissue, presents challenges with cryo-sectioning, often resulting in artifacts that can make histopathologic interpretation and correlation with other imaging modalities virtually impossible. We present an optimized on-block H&E staining technique that improves contrast for identifying collagenous stroma during cryo-fluorescence tomography (CFT) sectioning.

View Article and Find Full Text PDF

Evaluation of glomerular filtration rate estimation through plasma clearance of iohexol in seagulls (Larus michahellis).

BMC Vet Res

January 2025

Department of Veterinary Sciences, Veterinary Teaching Hospital "Mario Modenato", University of Pisa, via Livornese snc, San Piero a Grado, Pisa, Italy.

Background: Current endogenous indicators utilised in avian medicine are not sensitive enough to detect renal disease in its early stages. Alternative markers ought to be examined as a result. The aim is to investigate the accuracy of limited-sampling models for glomerular filtration rate (GFR) in adult seagulls using plasma clearance of iohexol (IOX).

View Article and Find Full Text PDF

Companion animal and equine clinical research: a Nordic perspective.

Acta Vet Scand

January 2025

Department of Clinical Sciences, Faculty of Veterinary Medicine and Animal Science, Swedish University of Agricultural Sciences, PO Box 7054, 750 07, Uppsala, Sweden.

Background: The societal value of cats, dogs and horses is high, and the companion and sport animal health care sector is growing. Clinical research concerning cats, dogs and horses is crucial for the development of evidence-based medical care that benefits animals and their owners, and has implications for human and environmental health from a One Health perspective. Basic information on companion animal and equine research enables more directed measures to improve conditions for research within the area.

View Article and Find Full Text PDF

Background: Spinal epidural arachnoid cysts (SEACs) are rare, non-neoplastic pathologies that can cause compressive myelopathy. Preoperative identification of the exact fistula location is crucial for minimally invasive management.

Methods: This single-center retrospective study included 27 patients with SEACs who underwent "double-needle puncture myelography" to precisely localize the fistula before minimally invasive surgery.

View Article and Find Full Text PDF

Objective: Patient characteristics, iodine injection, and scanning parameters can impact the quality and consistency of contrast enhancement of hepatic parenchyma in CT imaging. Improving the consistency and adequacy of contrast enhancement can enhance diagnostic accuracy and reduce clinical practice variability, with added positive implications for safety and cost-effectiveness in the use of contrast medium. We developed a clinical tool that uses patient attributes (height, weight, sex, age) to predict hepatic enhancement and suggest alternative injection/scanning parameters to optimize the procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!