A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of Keratoconus Specific to Standard IOL Formulas in Patients With Keratoconus Undergoing Cataract Surgery. | LitMetric

Purpose: To assess the performance of multiple intraocular lens (IOL) formulas in eyes with keratoconus.

Methods: Eyes with stable keratoconus scheduled for cataract surgery with biometry measurements on the Lenstar LS900 (Haag-Streit) were included. Prediction errors were calculated using 11 different formulas, including two with keratoconus modifiers. Primary outcomes compared standard deviations, mean and median numerical errors, and percentage of eyes within diopter (D) ranges across all eyes with subgroup analysis according to anterior keratometric values.

Results: Sixty-eight eyes from 44 patients were identified. In eyes with keratometric values less than 50.00 D, prediction error standard deviations ranged from 0.680 to 0.857 D. Percentages of eyes within ±0.50 D of target ranged from 57.89% to 73.68% with no statistical differences among formulas. In eyes with a keratometric value of more than 50.00 D, prediction error standard deviations ranged from 1.849 to 2.349 D and were not statistically different with heteroscedastic analysis; percentages of eyes within ±0.50 D of target ranged from 0% to 18.18% with no statistical differences among formulas. Only keratoconus-specific formulas (Barrett-KC and Kane-KC) and the Wang-Koch axial length adjustment version of SRK/T resulted in median numerical errors not significantly different than 0, regardless of keratometric values.

Conclusions: In keratoconic eyes, IOL formulas are less accurate than in normal eyes and result in hyperopic refractive outcomes that increase with steeper keratometric values. Using keratoconus-specific formulas and the Wang-Koch axial length adjustment version of SRK/T for axial lengths of 25.2 mm or greater improved IOL power prediction accuracy compared to other formulas. .

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20230124-01DOI Listing

Publication Analysis

Top Keywords

iol formulas
12
standard deviations
12
eyes
11
formulas
9
cataract surgery
8
formulas eyes
8
median numerical
8
numerical errors
8
eyes keratometric
8
keratometric values
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!