A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Magnetic nanoparticle loaded biodegradable vascular stents for magnetic resonance imaging and long-term visualization. | LitMetric

Magnetic nanoparticle loaded biodegradable vascular stents for magnetic resonance imaging and long-term visualization.

J Mater Chem B

Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing 211189, China.

Published: April 2023

Benefiting from their good biosafety and bioabsorbability, polymeric biodegradable stents (BDSs) have promising application prospects in the treatment of cardiovascular diseases. However, due to the low density of the polymer itself, it is difficult to visualize with medical imaging techniques such as CT and MRI, which leads to difficulties in accurate BDS localization and subsequent non-invasive evaluation. Therefore, modification of BDSs to adapt to monitoring techniques for clinical use without affecting their biocompatibility and mechanical properties is a promising strategy to support the clinical translation of BDSs. In this study, FeO superparamagnetic iron oxide nanoparticles (SPIONs) were synthesized to modify the BDS by ultrasonic spraying. Due to the -weighted MR imaging enhancement capability of SPIONs, the fabricated SPION-BDS can be entirely visualized and long-term monitored under MR imaging. Further, a stent degradation assessment method based on the analysis of image gray value changes was established. In conclusion, the constructed SPION-BDS provides a possible solution for precise localization of BDSs after implantation, and furthermore, opens up opportunities for long-term non-invasive monitoring of BDS degradation and multimodal imaging assessment of vascular endothelial remodeling.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3tb00185gDOI Listing

Publication Analysis

Top Keywords

imaging
5
magnetic nanoparticle
4
nanoparticle loaded
4
loaded biodegradable
4
biodegradable vascular
4
vascular stents
4
stents magnetic
4
magnetic resonance
4
resonance imaging
4
imaging long-term
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!