A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of expandable versus static lordotic interbody implants in minimally invasive spine surgery: patient reported outcomes, sagittal alignment, and restoration of disc height and foraminal height. | LitMetric

Background: Pain and disability due to age-related spinal disorders are increasing due to a more active population placing greater demands on their musculoskeletal system. For patients requiring surgery, spinal fusion is typically indicated. Interbody fusion cages improve fusion rates and restore lordosis, disc height, and foraminal height. Static cages are offered in multiple conformations to account for anatomic variability; however, they have issues related to implant subsidence and loss of lordosis. Expandable cages were developed to address these drawbacks.

Methods: Patients treated with either static or expandable transforaminal lumbar interbody fusion devices (ProLift Expandable Spacer System) for the treatment of spondylolisthesis, degenerative disc disease, spinal stenosis, disc herniation, or degenerative scoliosis at L4-L5 or L5-S1 were chosen from retrospective data. Outcomes included radiographic and spinopelvic changes, patient-reported outcomes, and incidence of non-union and revision surgery.

Results: One hundred patients were included (Static: 50; Expandable: 50). Demographics between groups were similar, with some differences in comorbidities and spinal disease diagnosis. Radiographically, changes in disc height, foraminal height, and lordosis were significantly improved in the Expandable group up to 2 years (P<0.001). Improvements in patient reported outcomes were more favorable in the Expandable group.

Conclusions: In patients who underwent transforaminal lumbar spinal fusion via minimally invasive surgery, the Expandable device group demonstrated significantly improved radiographic and patient reported outcomes compared to a static cage over 2 years.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10082426PMC
http://dx.doi.org/10.21037/jss-22-55DOI Listing

Publication Analysis

Top Keywords

disc height
12
height foraminal
12
foraminal height
12
interbody fusion
8
static expandable
8
expandable
6
height
6
disc
5
expandable versus
4
static
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!