The use of artificial intelligence (AI) in the diagnosis of dry eye disease (DED) remains limited due to the lack of standardized image formats and analysis models. To overcome these issues, we used the Smart Eye Camera (SEC), a video-recordable slit-lamp device, and collected videos of the anterior segment of the eye. This study aimed to evaluate the accuracy of the AI algorithm in estimating the tear film breakup time and apply this model for the diagnosis of DED according to the Asia Dry Eye Society (ADES) DED diagnostic criteria. Using the retrospectively corrected DED videos of 158 eyes from 79 patients, 22,172 frames were annotated by the DED specialist to label whether or not the frame had breakup. The AI algorithm was developed using the training dataset and machine learning. The DED criteria of the ADES was used to determine the diagnostic performance. The accuracy of tear film breakup time estimation was 0.789 (95% confidence interval (CI) 0.769-0.809), and the area under the receiver operating characteristic curve of this AI model was 0.877 (95% CI 0.861-0.893). The sensitivity and specificity of this AI model for the diagnosis of DED was 0.778 (95% CI 0.572-0.912) and 0.857 (95% CI 0.564-0.866), respectively. We successfully developed a novel AI-based diagnostic model for DED. Our diagnostic model has the potential to enable ophthalmology examination outside hospitals and clinics.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10085985 | PMC |
http://dx.doi.org/10.1038/s41598-023-33021-5 | DOI Listing |
Int Ophthalmol
January 2025
Second Department of Ophthalmology, The First People's Hospital of Aksu, Aksu, 843000, Xinjiang Autonomous Region, China.
Purpose: We aimed to evaluate the effects of autologous serum plus artificial tears on corneal sensation and tear film stability in patients with mild to moderate xerophthalmia after cataract surgery.
Methods: A total of 150 patients with mild to moderate xerophthalmia after one-time cataract surgery from March 2022 to September 2023 were selected and randomly divided into a control group (n = 75) and a study group (n = 75). The control group was treated with artificial tears (polyvinyl alcohol eye drops), while the study group was given autologous serum plus artificial tears.
Bioengineering (Basel)
January 2025
Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore 169856, Singapore.
Terahertz (THz) waves reside in the electromagnetic spectrum between the microwave and infrared bands. In recent decades, THz technology has demonstrated its potential for biomedical applications. With the highly unique characteristics of THz waves, such as the high sensitivity to water and optimal spatial resolution coupled with the characteristics of the human cornea, such as its high water content, THz technology has been explored as a potential modality to assess corneas and corneal diseases.
View Article and Find Full Text PDFJ Ophthalmol
January 2025
Department of Ophthalmology, Oslo University Hospital, P.O. Box 4950, Nydalen, Oslo 0424, Norway.
Dry eye disease (DED) is a multifactorial disorder affecting millions worldwide. Inflammation plays a central role in DED. The aim of this review is to critically evaluate the literature concerning the efficacy and safety of lifitegrast, a small molecule immunomodulator that blocks the action of lymphocyte function-associated antigen-1.
View Article and Find Full Text PDFLife Sci
January 2025
Department of Ophthalmology, Zhujiang Hospital, Southern Medical University, Guangzhou 510282, China. Electronic address:
Background: Diabetes-associated dry eye syndrome (DMDES) affects 20-54 % of diabetes, leading to ocular irritation and blurry vision. Decreased conjunctival goblet cell mucus secretion is one of the major pathological processes of DMDES. This study aims to investigate the mechanism of mucus granule maturation and secretion disturbance in DMDES.
View Article and Find Full Text PDFOcul Surf
January 2025
Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; College of Health & Life Sciences, School of Optometry, Aston University, Birmingham, UK.
Aim: Disease misdiagnosis is more likely if standardised diagnostic criteria are not used. This study systematically examined the effect on diagnosing dry eye disease (DED), when tests for evaluating tear film homeostasis were included/excluded from a multi-test protocol.
Method: For 1427 participants across five sites, data for the full suite of diagnostic tests defined in the Tear Film and Ocular Surface Society Dry Eye Workshop II (TFOS DEWS II) Diagnostic Methodology report algorithm were evaluated; diagnostic sensitivity was calculated when individual signs were removed, and when different combinations of signs were required.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!