Background: Peripheral intravenous catheter (PIVC) postinsertion failure rates are unacceptable. Ultrasonography is an adjunctive tool that may improve PIVC utilization success.
Objectives: Determine if ultrasonographically guided (USG) PIVCs placed in the emergency department (ED) significantly decreases postinsertion failure rate, increases utility time, and decreases postremoval complication rate. Determine if catheter-to-vein ratio (CVR) predicts postinsertion failure.
Methods: Participants were randomized to either standard or USG cohort. Data collection included participant and PIVC characteristics, vein measurements, postinsertion failure, and postremoval complication. Chi-square analysis compared postinsertion failure rates. Group t-test compared utility times. Postremoval complication rates were compared with standard rate analysis. The receiver operating characteristic curve was calculated to determine if CVR could predict postinsertion failure. An enrollment of 582 was estimated.
Results: A total of 223 patients were enrolled, with 222 PIVCs investigated. Standard cohort included 116 PIVCs and USG cohort included 106 PIVCs. A total of 212 vein diameters were analyzed. USG PIVC insertion did not result in fewer postinsertion failures (p = 0.654) or longer utility time (p = 0.808). Postremoval complications were not significantly lower (p = 0.414). Receiver operating characteristic curve showed a cut-off CVR of ∼ 0.21. Area under the curve was 0.621 (p = 0.063, 95% confidence interval 0.508-0.734).
Conclusion: The USG technique did not decrease postinsertion failure rate, increase utility time, or significantly decrease postremoval complication rate. A CVR predictive of postinsertion failure could not be determined.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jemermed.2023.02.011 | DOI Listing |
Ren Fail
December 2024
Department of Nephrology, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
Objective: Single- and double-purse-string suture methods are both widely used in open surgical catheterization for peritoneal dialysis. This study aimed to compare the post-insertion complications and technical survival of the two methods.
Methods: This retrospective study matched 142 patients who underwent peritoneal catheterization using the single- (Group S) or double- (Group D) purse-string suture method.
Open Vet J
September 2024
Division of Reproduction, Obstetrics and Gynaecology, School of Veterinary Medicine and Biomedical Sciences, IPB University, Bogor, Indonesia.
Background: An intravaginal device (IVD) made from polyethylene plastic and copper wire, integrated with a radio frequency identification (RFID) chip, was developed as a biocompatible contraceptive and identity device for cats.
Aim: This study evaluates the local and systemic biocompatibility of IVD in five non-pregnant female cats.
Methods: The IVD was successfully inserted into the vaginal lumen after estrogen administration.
BMC Oral Health
August 2024
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, PR China.
Background: Multi-rooted teeth with extensive dental defects often face challenges in stability and biomechanical failure. High-performance polymer PEEK materials, with properties closer to dentin, show promise in reducing stress concentration and preserving tooth structure. This report aimed to explore the use of a highly retentive polyetheretherketone (PEEK) for manufacturing custom-made split post and core for the restoration of grossly destroyed endodontically treated molars.
View Article and Find Full Text PDFJ Clin Med
June 2024
Surgical, Medical, Dental and Morphological Sciences Department (CHIMOMO), University of Modena and Reggio Emilia, 41126 Modena, Italy.
: The necessity of using central venous catheters (CVCs) in hemodialysis, coupled with their associated complications, remains a critical concern in nephrology. This study aims to compare the short-term prognosis of tunneled (T-CVC) and non-tunneled (NT-CVC) CVCs in acute hemodialysis patients, specifically focusing on infection rates, malpositioning, and lumen thrombosis within the first three weeks post-insertion. : A retrospective analysis was conducted on 176 CVCs placed between January and December 2023 at the Policlinico di Modena and the Ospedale Civile di Baggiovara.
View Article and Find Full Text PDFJ Pharm Bioallied Sci
April 2024
Department of Restorative Dentistry, College of Dentistry in Ar Rass, Qassim University, Kingdom of Saudi Arabia.
The stainless-steel crown (SSC) is a durable restoration and has several indications for use in primary teeth such as following a pulpotomy/pulpectomy, fractured teeth, teeth with developmental defects, or large multi-surface caries lesions where amalgam is likely to fail. Due to its durability and a lifespan like the primary tooth, it could well be the gold standard in restorative care. SSCs protect the crown from fracture, reduce the possibility for leakage, and ensure a biological seal.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!