Background: Peripheral intravenous catheter (PIVC) postinsertion failure rates are unacceptable. Ultrasonography is an adjunctive tool that may improve PIVC utilization success.

Objectives: Determine if ultrasonographically guided (USG) PIVCs placed in the emergency department (ED) significantly decreases postinsertion failure rate, increases utility time, and decreases postremoval complication rate. Determine if catheter-to-vein ratio (CVR) predicts postinsertion failure.

Methods: Participants were randomized to either standard or USG cohort. Data collection included participant and PIVC characteristics, vein measurements, postinsertion failure, and postremoval complication. Chi-square analysis compared postinsertion failure rates. Group t-test compared utility times. Postremoval complication rates were compared with standard rate analysis. The receiver operating characteristic curve was calculated to determine if CVR could predict postinsertion failure. An enrollment of 582 was estimated.

Results: A total of 223 patients were enrolled, with 222 PIVCs investigated. Standard cohort included 116 PIVCs and USG cohort included 106 PIVCs. A total of 212 vein diameters were analyzed. USG PIVC insertion did not result in fewer postinsertion failures (p = 0.654) or longer utility time (p = 0.808). Postremoval complications were not significantly lower (p = 0.414). Receiver operating characteristic curve showed a cut-off CVR of ∼ 0.21. Area under the curve was 0.621 (p = 0.063, 95% confidence interval 0.508-0.734).

Conclusion: The USG technique did not decrease postinsertion failure rate, increase utility time, or significantly decrease postremoval complication rate. A CVR predictive of postinsertion failure could not be determined.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jemermed.2023.02.011DOI Listing

Publication Analysis

Top Keywords

postinsertion failure
32
postremoval complication
16
utility time
12
postinsertion
10
peripheral intravenous
8
intravenous catheter
8
catheter-to-vein ratio
8
failure
8
failure rates
8
failure rate
8

Similar Publications

Objective: Single- and double-purse-string suture methods are both widely used in open surgical catheterization for peritoneal dialysis. This study aimed to compare the post-insertion complications and technical survival of the two methods.

Methods: This retrospective study matched 142 patients who underwent peritoneal catheterization using the single- (Group S) or double- (Group D) purse-string suture method.

View Article and Find Full Text PDF

Biocompatibility assessment of an integrated contraceptive and RFID-based intravaginal device in cats (): A preliminary study.

Open Vet J

September 2024

Division of Reproduction, Obstetrics and Gynaecology, School of Veterinary Medicine and Biomedical Sciences, IPB University, Bogor, Indonesia.

Background: An intravaginal device (IVD) made from polyethylene plastic and copper wire, integrated with a radio frequency identification (RFID) chip, was developed as a biocompatible contraceptive and identity device for cats.

Aim: This study evaluates the local and systemic biocompatibility of IVD in five non-pregnant female cats.

Methods: The IVD was successfully inserted into the vaginal lumen after estrogen administration.

View Article and Find Full Text PDF

Polyetheretherketone split post and core for restoration of multirooted molar with insufficient dental tissue remnants by digital techniques: a case report and 3-year follow up.

BMC Oral Health

August 2024

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, PR China.

Background: Multi-rooted teeth with extensive dental defects often face challenges in stability and biomechanical failure. High-performance polymer PEEK materials, with properties closer to dentin, show promise in reducing stress concentration and preserving tooth structure. This report aimed to explore the use of a highly retentive polyetheretherketone (PEEK) for manufacturing custom-made split post and core for the restoration of grossly destroyed endodontically treated molars.

View Article and Find Full Text PDF

: The necessity of using central venous catheters (CVCs) in hemodialysis, coupled with their associated complications, remains a critical concern in nephrology. This study aims to compare the short-term prognosis of tunneled (T-CVC) and non-tunneled (NT-CVC) CVCs in acute hemodialysis patients, specifically focusing on infection rates, malpositioning, and lumen thrombosis within the first three weeks post-insertion. : A retrospective analysis was conducted on 176 CVCs placed between January and December 2023 at the Policlinico di Modena and the Ospedale Civile di Baggiovara.

View Article and Find Full Text PDF

The stainless-steel crown (SSC) is a durable restoration and has several indications for use in primary teeth such as following a pulpotomy/pulpectomy, fractured teeth, teeth with developmental defects, or large multi-surface caries lesions where amalgam is likely to fail. Due to its durability and a lifespan like the primary tooth, it could well be the gold standard in restorative care. SSCs protect the crown from fracture, reduce the possibility for leakage, and ensure a biological seal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!