Introduction: Chorioamniotic membrane separation (CAS), preterm prelabor rupture of membranes (PPROM), and preterm delivery (PTD) remain as major complications of fetoscopic laser photocoagulation (FLP) for twin-to-twin transfusion syndrome (TTTS). We sought to examine whether use of Quincke-tip needles for initial entry during FLP reduces the risk of these complications.
Methods: This is a secondary analysis of prospectively collected data from patients that had FLP for TTTS at a single tertiary care center (2011-2021). We excluded patients for whom direct trocar entry was used. Patients for whom a Quincke-tip needle was used were compared to those for whom a diamond-tip needle was used during Seldinger entry. Demographics, ultrasound findings and operative characteristics were compared between groups. Postoperative outcomes and complications (including CAS, PPROM, and PTD) were also compared. Multivariate logistic regression models were fit to assess independent risk factors for complications.
Results: 386 patients met inclusion criteria; Quincke-tip needles were used in 81 (21.0%) cases, while diamond-tip needles were used in 305 (79.0%). Rates of CAS (11.1 vs. 9.5%, p = 0.67) and PPROM (44.4 vs. 41.0%, p = 0.57) were similar between groups. Patients in the Quincke-tip group delivered 1.5 weeks earlier than those in the diamond-tip group (30.5 vs. 32.0 weeks, p = 0.01). However, these patients were more likely to be delivered for maternal (35.9 vs. 19.0%) and fetal (23.1 vs. 15.3%) indications (p < 0.01). In multivariate analysis, needle type was not identified as an independent risk factor for PPROM. However, Quincke-tip needle use was associated with PTD less than 32 weeks (aOR 1.74, 95% CI: 1.02-2.97, p = 0.043).
Conclusion: Membrane complications following FLP were not associated with the needle type used for entry. Earlier delivery in the Quincke-tip group was likely attributable to higher rates of delivery for maternal and fetal indications, and not membrane complications. The needle chosen for entry is likely best determined by operator preference.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000530548 | DOI Listing |
Fetal Diagn Ther
August 2023
Department of Obstetrics, Gynecology, and Reproductive Sciences, University of Texas, McGovern Medical School, Houston, Texas, USA.
Introduction: Chorioamniotic membrane separation (CAS), preterm prelabor rupture of membranes (PPROM), and preterm delivery (PTD) remain as major complications of fetoscopic laser photocoagulation (FLP) for twin-to-twin transfusion syndrome (TTTS). We sought to examine whether use of Quincke-tip needles for initial entry during FLP reduces the risk of these complications.
Methods: This is a secondary analysis of prospectively collected data from patients that had FLP for TTTS at a single tertiary care center (2011-2021).
Micron
April 2022
Mechanical Metallurgy Laboratory, École Polytechnique Fédérale de Lausanne (EPFL), MXD 140 (Bâtiment MXD), Station 12, CH-1015 Lausanne, Switzerland. Electronic address:
Microprobe tips are commonly used to perform in-situ micromechanical tests within an electron microscope. In service, such tips have a tendency to accumulate along their surface a layer of deposited material. Tip cleanliness is crucial in order to obtain reliable and reproducible data; however, cleaning of such tips can be arduous, due to their fragility.
View Article and Find Full Text PDFJPRAS Open
September 2019
Otolaryngology Department, The Royal Wolverhampton Hospitals NHS Trust, New Cross Hospital, Wolverhampton Road, Wolverhampton, West Midlands WV10 0QP, United Kingdom.
Septoplasties and septorhinoplasties are common procedures in otolaryngology, aimed at addressing septal and/or bony pyramidal deflections to improve functional and cosmetic outcomes. The nasal septum as well as regulating air flow provides structural support to the nasal tip. The attachment of the nasal septum to the anterior nasal spine must be structurally resilient to prevent saddling or tip ptosis.
View Article and Find Full Text PDFUltramicroscopy
July 2019
Laboratoire Collisions Agrégats Réactivité, Université de Toulouse, UPS, CNRS, France. Electronic address:
We report results of experimental investigation of field electron emission from diamond nanoemitters. The measurements were performed with single crystal diamond needles fixed at tungsten tips. The voltage drop along diamond needles during emission was revealed and measured using electron energy spectroscopy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!