Background: Breast implant-related complications can be reduced by strict antiseptic precautions during insertion, but bacteria can often be found on implant surfaces on the occasion of revision surgery. The authors prospectively analyzed the association of bacteria found on breast implant surfaces with implant-related complications in breast implant revision cases.

Methods: The authors analyzed a total of 100 breast implant revisions in 66 patients between August of 2018 and January of 2021. Capsular swabs and capsular samples were taken intraoperatively. Analyses on the occurrence of bacteria and the occurrence of implant-related complications were performed. In addition, correlations between bacteria-contaminated breast implant surfaces and implant-related complications were performed.

Results: Implant-related complications (perforation, rupture, capsular contraction) were observed in 42 implant sites: eight unilateral and 34 bilateral cases. In total, 16 swabs showed positive bacterial growth, 10 of which were associated with a breast implant-related complication (χ 2 = x, y, and z; P = 0.006). The most common implant-based complication at contaminated prosthetics was implant rupture. The association of contaminated breast implants and implant rupture was statistically significant.

Conclusions: The authors identified a correlation between implant complications and Gram-positive bacteria found on breast implant surfaces. The most common implant-based complication seen at simultaneously positive samples was implant rupture in 50% of the authors' cases. No capsular contraction or other complications were seen.

Clinical Question/level Of Evidence: Risk, III.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10729897PMC
http://dx.doi.org/10.1097/PRS.0000000000010499DOI Listing

Publication Analysis

Top Keywords

implant-related complications
24
breast implant
20
implant surfaces
16
breast implant-related
12
implant rupture
12
implant
11
breast
9
gram-positive bacteria
8
complications
8
bacteria breast
8

Similar Publications

Purpose: To evaluate the long-term outcomes of enucleation without conjunctival closure in a large patient cohort.

Methods: A retrospective chart review was conducted from January 2011 to January 2024, examining 144 eyes of 143 patients who underwent enucleation without conjunctival closure by a single oculoplastic surgeon. Data collected included patient demographics, indications for surgery, implant types, and complications.

View Article and Find Full Text PDF

Minimally Invasive Placement of Cannulated Headless Compression Screws for Reduction of Sacroiliac Luxation in 14 Cats.

Vet Comp Orthop Traumatol

December 2024

Surgery Department, Evidensia Dierenziekenhuis Hart van Brabant, Waalwijk, Brabant, The Netherlands.

Objective:  To describe percutaneous fluoroscopy-guided placement of self-drilling, self-tapping, 3.0 mm cannulated headless compression screws (HCS) for surgical reduction of sacroiliac luxation (SIL) in cats, and to document clinical outcome.

Materials And Methods:  Medical records of cats with SIL, managed by percutaneous fluoroscopy-guided placement of a 3.

View Article and Find Full Text PDF

Background: Pelvic reconstruction after type I + II (or type I + II + III) internal hemipelvectomy with extensive ilium removal is a great challenge. In an attempt to anatomically reconstruct the hip rotation center (HRC) and achieve a low mechanical failure rate, a custom-made, 3D-printed prosthesis with a porous articular interface was developed. The aim of this study was to investigate the clinical outcomes of patients treated with this prosthesis.

View Article and Find Full Text PDF

Objective: The objective of this study was to compare a multiple pelvic screw fixation strategy (dual bilateral 4 pelvic screw fixation [4PvS]) with the use of single bilateral 2 pelvic screw fixation (2PvS), with the aim of addressing lumbosacral junction stability.

Methods: This analysis is a single-center, retrospective review of ASD patients treated between 2015 and 2021. All patients had a minimum 2-year follow-up and spinal fusion to the sacrum without sacroiliac fusion and met at least one radiographic and procedural criterion: pelvic incidence-lumbar lordosis ≥ 20°, T1 pelvic angle ≥ 20°, sagittal vertical axis ≥ 7.

View Article and Find Full Text PDF

Persistent numbness of the lower lip and chin due to inferior alveolar nerve injury after implant placement: A clinical report.

Prim Dent J

December 2024

Ilser Turkyilmaz DMD, PhD Associate Dean of Digital Innovation, Professor and Chair, Department of Comprehensive Care, School of Dental Medicine, Case Western Reserve University, Cleveland, Ohio, USA.

The number of dental implants placed and restored every year is increasing across the world. However, there has been an increase in the number of reports with implant-related surgical complications in which the inferior alveolar nerve injury is the most serious one. This surgical problem can be avoided by using cone beam computed tomography (CBCT), three-dimensional (3D) implant planning software, and computer-aided design and computer-aided manufacturing (CAD-CAM) technology such as stereolithographic surgical guides.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!