Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In the field of biomechanics, numerical procedures can be used to understand complex phenomena that cannot be analyzed with experimental setups. The use of experimental data from human cadavers can present ethical issues that can be avoided by utilizing biofidelic models. Biofidelic models have been shown to have far-reaching benefits, particularly in evaluating the effectiveness of protective devices such as body armors. For instance, numerical twins coupled with a biomechanical model can be used to assess the efficacy of protective devices against intense external forces. Similarly, the use of human body surrogates in experimental studies has allowed for biomechanical studies, as demonstrated by the development of crash test dummies that are commonly used in automotive testing. This study proposes using numerical procedures and simplifying the structure of an existing biofidelic FE model of the human thorax as a preliminary step in building a physical surrogate. A reverse engineering method was used to ensure the use of manufacturable materials, which resulted in a FE model called SurHUByx FEM (Surrogate HUByx Finite Element Model, with HUByx being the original thorax FE model developed previously). This new simplified model was validated against existing experimental data on cadavers in the context of ballistic impact. SurHUByx FEM, with its new material properties of manufacturable materials, demonstrated consistent behavior with the corresponding biomechanical corridors derived from these experiments. The validation process of this new simplified FE model yielded satisfactory results and is the first step towards the development of its physical twin using manufacturable materials.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10073536 | PMC |
http://dx.doi.org/10.3389/fbioe.2023.1152508 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!