Background: Three-dimensional preoperative planning has been applied to the osteosynthesis of distal humerus fractures. The present study investigated the correlations between 3D preoperative planning and postoperative reduction for the osteosynthesis of distal humerus fractures using 3D parameters.
Methods: Twenty-three elbows of 23 distal humerus fracture patients who underwent osteosynthesis with three-dimensional preoperative planning were evaluated. 3D images of the distal humerus were created after taking preoperative CT scans of the injured elbow. Fracture reduction, implant selection, and placement simulations were performed based on 3D images. Postoperative CT images were taken 1 month after surgery. Correlations were evaluated with preoperative plans and postoperative 3D images. The longitudinal axis and coordinates of the humerus were defined on the 3D images. The coronal angle (CA) was defined as the angle formed by the long axis and the line connecting the medial and lateral margins of the trochlea of the humerus on a coronal plane image. The sagittal angle (SA) was defined as the angle formed by the long axis and the line connecting the top of the lateral epicondyle and the center of the humeral capitellum on a sagittal plane image. The axial angle (AA) was defined as the angle between the sagittal plane and the line connecting the medial and lateral margins behind the trochlea of the humerus. The intraclass correlation coefficients (ICC) of each measurement value were assessed between preoperative planning and postoperative images.
Results: Preoperative planning and postoperative measurement values were CA: 85.6 ± 5.9°/85.8 ± 5.9°, SA: 140.9 ± 8.5°/139.4 ± 7.9°, and AA: 84.0 ± 3.1°/82.6 ± 4.9°, respectively. ICCs were CA: 0.75 (P < 0.01), SA: 0.78 (P < 0.01), and AA: 0.34 (P < 0.05), respectively.
Conclusions: The 3D preoperative planning of distal humeral fractures achieved the good correlations of coronal and sagittal angles, but the relatively poor correlation of the axial angle. This may be attributed to an inability to assess the rotation angle during surgery. We propose the measurement indices shown in the present study as a three-dimensional evaluation index for distal humerus fractures.
Trial Registration: Registered as NCT04349319 at ClinicalTrials.gov.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10082491 | PMC |
http://dx.doi.org/10.1186/s13018-023-03772-y | DOI Listing |
J Prosthet Dent
January 2025
Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
The preoperative fabrication of well-contoured, computer-aided design and computer-aided manufacturing (CAD-CAM), custom healing abutments is essential for guiding soft tissue healing and saving chairside time. This dental technique involves a fully digital workflow to fabricate a CAD-CAM custom healing abutment that relies on preoperative digital implant planning. The healing abutment is designed with an optimal emergence profile that can predictably direct the anatomy of the peri-implant mucosa.
View Article and Find Full Text PDFJ Plast Reconstr Aesthet Surg
December 2024
Department of Hand and Plastic Surgery, Thurgau Hospital Group, Frauenfeld, Switzerland; Division of Hand, Plastic and Aesthetic Surgery University Hospital, LMU Munich, Germany.
The distance between the mid-clavicle and nipple (MCN) is crucial in planning reduction mammoplasties. MCN has been shown to be superior in achieving nipple-areola complex symmetry. However, there is great variability in clavicle anatomy.
View Article and Find Full Text PDFAnn Plast Surg
December 2024
Department of Biomedical Engineering, Taipei Veterans General Hospital, Taipei, Taiwan.
Background: Surgical treatment of comminuted and multiple facial fractures is challenging, as identifying the bone anatomy and restoring the alignment are complicated. To overcome the difficulties, 3D-printed "jigsaw puzzle" has been innovated to improve the surgical outcome. This study aimed to demonstrate the feasibility of 3D-printed model in facial fracture restoration procedures.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Physical and Rehabilitation Medicine, Turku University Hospital and University of Turku, Turku, Finland.
Background And Aims: Previous studies in lumbar spine surgery have mainly studied functioning and pain by comparing average scores from Patient Reported Outcome Measures (PROMs) at different time points. Less is known about these changes in different subgroups. It is self-evident that, while most patients may demonstrate trajectories of these changes close to the average one, some groups may follow more or less different trends.
View Article and Find Full Text PDFWorld J Urol
January 2025
Department of Urology, Dokkyo Medical University Saitama Medical Center, Saitama, Japan.
Purpose: Preoperative C-reactive protein (CRP) is a valuable prognostic biomarker in nonmetastatic clear cell renal cell carcinoma (nmccRCC). Incorporation of CRP into prognostic models may improve the prediction of oncologic outcomes. Herein, we aimed to develop and validate prognostic nomograms and an integrated software incorporating preoperative CRP level in nmccRCC.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!