Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Successful endovascular treatment by stenting of intracranial aneurysms requires proper placement of the device and appropriate choice of its diameter and length. To date, several methods have been employed to achieve these goals, although each has inherent critical issues. Recently developed stent planning software applications can be used to assist interventional neuroradiologists. Based on a 3D-DSA image acquired before stenting, these applications simulate and visualize the final placement of the deployed stent. In this single-centre retrospective study, 27 patients undergoing an intravascular procedure for the treatment of intracranial aneurysms from June 2019 to July 2020 were evaluated according to strict inclusion criteria. Stent virtualization was performed with Syngo 3D Aneurysm Guidance Neuro software. We compared the software-generated stent measurement and measurements taken by the interventional radiologist. Statistical analysis was performed using the STAC web platform. Mean and standard deviations of absolute and relative discrepancies between predicted and implanted stents were recorded. Friedman's nonparametric test was used to refute the null hypotheses, i.e. (I) discrepancies between the size of virtual and implanted stents would occur, and (II) operator influence does not affect the outcome of the virtual stenting process. Based on these observations, it is believed that the virtual stenting process can validly assist interventional neuroradiologists in selecting the appropriate device and reducing peri- and post-procedural complications. The results of our study suggest that virtual reality simulation of devices used for endovascular treatment of intracranial aneurysms is a useful, rapid, and accurate tool for interventional procedure planning.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11547-023-01620-x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!