Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background & Objectives: Timely intervention is needed to minimize the economic losses of vector-borne bovine anaplasmosis which can be possible by the isothermal amplification assay.
Methods: Anaplasma marginale in the cattle of south Gujarat, India was detected in the PCR and LAMP by amplifying the fragment of msp5 gene. The PCR product was digested with EcoRI, and sequenced to confirm its pathogen specific detection.
Results: Species specific PCR observed a band of 457 bp of msp5 DNA following 1% agarose gel electrophoresis. Positive LAMP reaction turned into yellow colour while negative sample depicted original pink colour. A detection limit of PCR and LAMP was up to 10 and 10 of the original genomic DNA of A. marginale, respectively. A single cut site of EcoRI was observed in the PCR product. Current msp5 DNA sequences of A. marginale (MW538962 and MW538961) showed 100% homology with the published sequences. Monophyletic lineage type relationship was observed with high bootstrap proportion among the msp5 DNA sequences of A. marginale in the phylogram. Prevalence rate of A. marginale was significantly higher (p<0.05) in the PCR [43/280 (15.36%)] and LAMP [62/280 (22.14%)] than the microscopic technique [17/280 (6.07%)]. Diagnostic sensitivity, specificity, positive and negative predictive values at 95% CI for LAMP assay with respect to PCR were 93.02%, 90.72%, 64.52% and 98.62%, respectively.
Interpretation & Conclusion: Thus LAMP can be a practical alternative to the PCR for the diagnosis of A. marginale infection in the cattle even in field condition.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4103/0972-9062.353249 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!