A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and adherence of pressure garment therapy in children with upper limb unilateral cerebral palsy. Results from a randomized clinical trial ancillary analysis. | LitMetric

Background: This study was conducted to assess the safety and adherence of the use of a PGT (Pressure Garment Therapy) Lycra® sleeve to treat upper limb unilateral cerebral palsy (UCP) in children.

Methods: This study was conducted as a prospective, placebo-controlled, double-blinded, randomized monocenter study. Included in the study were 58 UCP children, 49 of whom were analyzed. 25 children (mean age 6.6 ± 1.6 years; 12 girls) were allocated to the active group vs. 24 (mean age 6.7 ± 1.6 years; 10 girls) in the placebo group. The intervention consisted of an active PGT Lycra® arm sleeve manufactured to generate a homogeneous pressure ranging from 15 to 25 mmHg. The placebo PGT Lycra® sleeve was manufactured to generate a homogeneous pressure under 7 mmHg. The time of wearing period was set at 3 h/day at minimum and 6 h/day at maximum, over the course of 6 months. The main outcome measures were safety outcomes including the number and intensity of Adverse Events of Special Interest (AESIs). AESIs were defined as adverse events imputable to compressive therapy and Lycra® wearing. Level of adherence was expressed in percentage of number of days when the sleeve was worn for at least 3 h per day compared to length of duration in days (start and end date of wearing period).

Results: Frequency of AESIs were very low and no different between groups (4.12 ± 11.32% vs. 1.83 ± 3.38%;  = 0.504). There were no differences in adherence (91.86 ± 13.86% vs. 94.30 ± 9.95%;  = 0.425).

Conclusion: The use of PGT Lycra® arm sleeve in children with UCP is safe and well-tolerated with a very good adherence. The low rate of AESIs is promising for further randomized clinical trials on efficacy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10071041PMC
http://dx.doi.org/10.3389/fped.2023.1043350DOI Listing

Publication Analysis

Top Keywords

pgt lycra®
12
safety adherence
8
pressure garment
8
garment therapy
8
upper limb
8
limb unilateral
8
unilateral cerebral
8
cerebral palsy
8
randomized clinical
8
study conducted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!