Owing to its unique penetrating power and high-resolution capability, X-ray imaging has been an irreplaceable tool since its discovery. Despite the significance, the resolution of X-ray imaging has largely been limited by the technical difficulties on X-ray lens making. Various lensless imaging methods have been proposed, but are yet relying on multiple measurements or additional constraints on measurements or samples. Here we present coherent speckle-correlation imaging (CSI) using a designed X-ray diffuser. CSI has no prerequisites for samples or measurements. Instead, from a single shot measurement, the complex sample field is retrieved based on the pseudorandomness of the speckle intensity pattern, ensured through a diffuser. We achieve a spatial resolution of 13.9 nm at 5.46 keV, beating the feature size of the diffuser used (300 nm). The high-resolution imaging capability is theoretically explained based on fundamental and practical limits. We expect the CSI to be a versatile tool for navigating the unexplored world of nanometer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10079858PMC
http://dx.doi.org/10.1038/s41377-023-01124-3DOI Listing

Publication Analysis

Top Keywords

x-ray imaging
12
imaging
6
x-ray
5
direct high-resolution
4
high-resolution x-ray
4
imaging exploiting
4
exploiting pseudorandomness
4
pseudorandomness unique
4
unique penetrating
4
penetrating power
4

Similar Publications

Background: Recent technological advances have introduced novel methods for measuring body composition, each with unique benefits and limitations. The choice of method often depends on the trade-offs between accuracy, cost, participant burden, and the ability to measure specific body composition compartments.

Objective: To review the considerations of cost, accuracy, portability, and participant burden in reference and emerging body composition assessment methods, and to evaluate their clinical applicability.

View Article and Find Full Text PDF

Development of an image quality evaluation system for bedside chest X-ray images using scatter correction processing.

Radiol Phys Technol

January 2025

Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-ogu, Arakawa, Tokyo, 116-8551, Japan.

In plain radiography, scattered X-ray correction processing (Virtual Grid: VG) is used to estimate and correct scattered rays in images. We developed an objective evaluation system for bedside chest X-ray images using VG and investigated its usefulness. First, we trained the blind/referenceless image spatial quality evaluator (BRISQUE) on 200 images obtained by portable chest radiography.

View Article and Find Full Text PDF

Objective: To identify clusters of women with similar trajectories of breast density change over four longitudinal assessments and to examine the association between these trajectories and the subsequent risk of breast cancer.

Design: Retrospective cohort study.

Setting: Data from the national breast cancer screening programme, which is embedded in the National Health Insurance Service database in Korea.

View Article and Find Full Text PDF

Smith-Magenis syndrome with Dandy-Walker malformation in a 2-year-old girl: A case report.

J Int Med Res

January 2025

Department of Cardiac Surgery, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou, Gansu, China.

Smith-Magenis syndrome (SMS) and Dandy-Walker malformation (DWM) are uncommon genetic conditions with nonspecific clinical features, which makes reaching a definitive diagnosis challenging. We describe here, a 2-year-old girl who was diagnosed with SMS at the age of 12 months due to delayed growth and development. The child presented to hospital with acute heart failure and respiratory failure.

View Article and Find Full Text PDF

Removal of spontaneously fractured leads with their proximal ends migrated into the vascular space has not been analysed in detail thus far. The study aimed to compare the effectiveness of different approaches and auxiliary tools for removing fractured leads with migrated proximal ends. Retrospective analysis of 72 cases from a database containing 3847 TLEs (transvenous lead extraction).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!