This paper presents the development of low-cost, disposable impedance-based sensors for real-time, in-line monitoring of suspension cell culture. The sensors consist of electrical discharge machining (EDM) cut aluminum electrodes and polydimethylsiloxane (PDMS) spacers, both of which are low-cost materials that can be safely disposed of. Our research demonstrates the capability of these low-cost sensors for in-line, non-invasive monitoring of suspension cell growth in cell manufacturing. We use a hybrid equivalent circuit model to extract key features/parameters from intertwined impedance signals, which are then fed to a novel physics-inspired (gray-box) model designed for α-relaxation. This model determines viable cell count (VCC), a critical quality attribute (CQA) in cell manufacturing. Predicted VCC trends are then compared with image-based cell count data to verify their accuracy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bioelechem.2023.108416 | DOI Listing |