A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inkjet-printed P(VDF-TrFE) film for high-frequency annular array. | LitMetric

An innovative processing to deposit P(VDF-TrFE) film on silicon wafers by an inkjet printing method was used to fabricate high-frequency annular array prototype. This prototype has a total aperture of 7.3 mm and 8 active elements. A polymer-based lens with low acoustic attenuation was added to the flat deposition on the wafer, setting the geometric focus to 13.8 mm. With a thickness of around 11 μm, the electromechanical performance of P(VDF-TrFE) films was evaluated with an effective thickness coupling factor of 22%. Electronics allowing all elements to simultaneously emit as a single element transducer was developed. In reception, a dynamic focusing, based on eight independent amplifying channels, was preferred. The center frequency of the prototype was 21.3 MHz, the insertion loss was 48.5 dB and the -6 dB fractional bandwidth was 143%. The trade-off sensitivity/bandwidth has rather favored the large bandwidth. Dynamic focusing on reception was applied and allowed to improvements in the lateral-full width at half maximum as shown on images obtained with a wire phantom at several depths. The next step, for a fully operational multi-element transducer, will be to achieve a significant increase of the acoustic attenuation in the silicon wafer.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2023.3242073DOI Listing

Publication Analysis

Top Keywords

pvdf-trfe film
8
high-frequency annular
8
annular array
8
acoustic attenuation
8
dynamic focusing
8
inkjet-printed pvdf-trfe
4
film high-frequency
4
array innovative
4
innovative processing
4
processing deposit
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!