Objective: The inverted triangle configuration of the three cannulated screws is the classic fixation method most commonly performed for undisplaced femoral neck fractures in young and geriatric patients. However, the posterosuperior screw has a high incidence of cortical breach, known as an in-out-in (IOI) screw. In this study, we present a novel posterosuperior screw placement strategy to prevent the screw from becoming IOI.
Methods: Using computed tomography data and image-processing software, 91 undisplaced femoral neck fractures were reconstructed. The anteroposterior (AP), lateral, and axial radiographs were simulated. To simulate the intraoperative screw placement process, participants used three screw insertion angles (0°, 10°, and 20°) to place the screw on the AP and lateral views of the radiograph according to the three established strategies. On the AP radiograph, a screw was placed abutting (strategy 1), 3.25 mm away from (strategy 2), or 6.5 mm away from (strategy 3) the superior border of the femoral neck. On the lateral radiograph, all the screws were placed abutting the posterior border of the femoral neck. Axial radiographs were used to evaluate the screw position.
Results: In strategy 1, all the placed screws were IOI regardless of the screw insertion angle. In strategy 2, 48.3% (44/91) of IOI screws occurred at a 0° screw insertion angle, 41.7% (38/91) of IOI screws occurred at a 10° screw insertion angle, and 42.9% (39/91) of IOI screws occurred at a 20° screw insertion angle situation. In strategy 3, no IOI screw occurred, and the screw insertion angles did not affect the safety and accuracy of screw placement.
Conclusions: Screws placed according to strategy 3 are safe. The reliability of this screw placement strategy is unaffected by a screw insertion angle of less than 20 degrees.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10069476 | PMC |
http://dx.doi.org/10.3389/fsurg.2023.1142135 | DOI Listing |
Oper Orthop Traumatol
December 2024
Department of Orthopedics and Traumatology, Centre Hospitalier Universitaire Vaudois, (CHUV), Rue de Bugnon 46, 1011, Lausanne, Switzerland.
Objective: Minimally invasive percutaneous techniques are used to stabilize fractures of the anterior pelvic ring. Stabilization of the fracture facilitates early mobilization and rehabilitation, while percutaneous techniques reduce complications such as infection and bleeding.
Indications: Indicated for patients with non- or minimally displaced fractures of the anterior pelvic ring, or if fracture displacement can be reduced using minimally invasive techniques.
Arthrosc Tech
November 2024
JMVM Sports Injury Centre, Sitaram Bhartia Institute of Science and Research, New Delhi, India.
Collateral injuries are usually found in association with cruciate ligament tears. There are multiple techniques to reconstruct the collateral ligaments using autografts and allografts. Conventionally, interference screws are used to fix the graft on the femur, tibia, and fibula.
View Article and Find Full Text PDFArthrosc Tech
November 2024
Department of Orthopedic Surgery, Hospital Clínico Universitario Valladolid, Valladolid, Spain.
The elbow is one of the most commonly dislocated joints. Although simple dislocations of the elbow usually resolve with conservative management, certain patients can experience residual chronic instability. Posterolateral rotational instability accounts for approximately 80% of elbow chronic instability cases.
View Article and Find Full Text PDFClin Oral Implants Res
December 2024
Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Objective: To assess the clinical, radiographic and patient-reported outcome measures, and the success of screw-retained one-piece monolithic zirconia implant-supported restorations in the posterior region during a 1-year follow-up.
Methods: In a prospective case series, 50 single molar sites in the posterior region of 41 patients with a minimum age of 18 years and sufficient bone volume for placing an implant (≥ 8 mm) and space for an anatomical restoration were included. Following prosthetic-driven digital three-dimensional treatment planning, a tissue-level implant with an internal connection was inserted during a one-stage surgical procedure.
Eur J Orthod
December 2024
Department of Dentistry, All India Institute of Medical Sciences, Basni Industrial Area Phase-2, Jodhpur- 342005, Rajasthan, India.
Background: The infrazygomatic miniscrew implants (IZC-MSI) serve as innovative temporary anchorage devices placed parallel to the roots of molars in the infrazygomatic crest region, leveraging their extra-radicular location to support the en masse distalization and intrusion of the maxillary dentition. The efficacy and stability of these screws are crucial for their application in contemporary orthodontic practices.
Objectives: This systematic review aimed to estimate the success rate and factors affecting the stability of IZC-MSI.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!