The maxillary artery (MA) is a key structure at risk of injury in numerous oral and maxillofacial surgical (OMS) procedures. Knowledge of safe distances from this vessel to surgically familiar bony landmarks could improve patient safety and prevent catastrophic haemorrhage. Distances between the MA and bony landmarks on the maxilla and mandible were measured using CT angiograms on 100 patients (200 facial halves). The vertical height of the pterygomaxillary junction (PMJ) was mean (SD) measurement of 16 (3) mm. The MA enters the pterygomaxillary fissure (PMF) a mean (SD) distance of 29 (3) mm from the most inferior point of the PMJ. The mean (SD) shortest distance between the MA and medial surface of the mandible was 2 (2) mm (with the vessel directly contacting the mandible in 17% of cases). The branchpoint (bifurcation of the superficial temporal artery (STA) and MA) was directly in contact with the mandible in 5% of cases. The mean (SD) distances between this bifurcation point and the medial pole of the condyle were 20 (5) mm and 22 (5) mm, respectively. A horizontal plane through the sigmoid notch perpendicular to the posterior border of the mandible is a good approximation of the trajectory of the MA. The branchpoint is usually within 5 mm of this line and inferior in 70% of cases. Surgeons should take note that both the branchpoint and the MA contact the surface of the mandible in a significant number of cases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bjoms.2022.11.004DOI Listing

Publication Analysis

Top Keywords

bony landmarks
12
maxillary artery
8
surface mandible
8
mandible
6
radiological analysis
4
analysis maxillary
4
artery relationships
4
relationships key
4
key bony
4
landmarks maxillofacial
4

Similar Publications

The present paper was designed to analyze the dimensions of such important bony structures and surgical landmarks, which are used by many clinicians in many surgical interventions, in dry skull, cadaver, and healthy subjects on computed tomography (CT) images, and to determine whether there is a significant difference between these methods, and to obtain reference values from 3 different methods. Eight cadavers and 16 dry skulls and 100 three-dimensional (3D) CT images were studied. Necessary permissions for the study were obtained from Ethics Comittee.

View Article and Find Full Text PDF

Placing an inertial measurement unit (IMU) at the 5th lumbar vertebra (L5) is a frequently employed method to assess the whole-body center of mass (CoM) motion during walking. However, such a fixed position approach does not account for instantaneous changes in body segment positions that change the CoM. Therefore, this study aimed to assess the congruence between CoM accelerations obtained from these two methods.

View Article and Find Full Text PDF

Anatomic-Based Diagnosis and Filler Injection Techniques: Chin Augmentation and Jawline Contouring.

J Craniofac Surg

January 2025

Department of Oral Biology, Division in Anatomy and Developmental Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry.

Chin augmentation and jawline contouring have emerged as significant procedures in aesthetic medicine, addressing both structural and age-related changes in the lower face. This review explores anatomic-based diagnosis and filler injection techniques for these treatments. Ethnic variations in facial structure necessitate different approaches, with Western patients often seeking jawline definition, while Asian patients frequently require chin projection.

View Article and Find Full Text PDF

Purpose: To clarify the femoral tunnel location for a virtual anterior cruciate ligament (ACL) graft to simulate the native ACL.

Methods: Three-dimensional (3D) computed tomography (CT) and magnetic resonance imaging (MRI) were obtained in 14 normal knees in full extension. Two types of virtual triple bundle ACL grafts (VACLG) were created.

View Article and Find Full Text PDF

Objective: To apply a network medicine-based approach to analyze the phenome of the prenatal fetal MRI and biometric findings in the Chiari II malformation (CM II) to detect specific patterns and co-occurrences.

Method: A single-center retrospective review of fetal MRI scans obtained in fetuses with CM II was performed. Co-occurrence analysis was utilized to generate a phenotypic comorbidity matrix and visualized by Gephi software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!