Background: Capsulorhexis is the most important step in intumescent cataract due to the high risk of radial extension of the capsular tear during the cataract surgery. The aim of this study is to present modified the two-stage capsulorhexis technique for intumescent cataract.

Materials And Methods: The two-stage capsulorhexis technique was used in this study. A small size capsulorhexis approximately 1.5-2 mm diameter was created in the first stage. Liquefied cortex was aspirated with a 25 G cannula to equalize anterior chamber pressure and intracapsular pressure after the small size capsulorhexis. In the second stage, a 5-6 mm capsulorhexis size was performed for a safe phacoemulsification.

Results: A total of 73 consecutive patients with intumescent cataract were evaluated in this study. There were 39 male cases and 34 female cases. Mean age was 66 years ± 8 (between 53 and 84 years). A well centered complete continuous curvilinear capsulorhexis approximately 5-6 mm size was achieved in 72 of 73 cases (98.6%). Peripheral extension of capsulorhexis occurred in one eye during the second stage capsulorhexis. In this case, the capsule was cut with Vannas scissors and the capsulorhexis was completed. The rest of surgery was continued with a standard procedure and in-the-bag IOL implantation was done.

Conclusions: This technique facilitates the creation of a safe capsulorhexis compared to the one-stage capsulorhexis technique. Surgeons may consider this technique to perform a safe phacoemulsification in the intumescent cataracts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10074661PMC
http://dx.doi.org/10.1186/s12886-023-02895-4DOI Listing

Publication Analysis

Top Keywords

capsulorhexis technique
16
capsulorhexis
14
technique intumescent
8
intumescent cataracts
8
modified two-stage
8
continuous curvilinear
8
curvilinear capsulorhexis
8
intumescent cataract
8
two-stage capsulorhexis
8
small size
8

Similar Publications

Introduction: In the era of functional intraocular lens (IOL) implantation, it is crucial to investigate the influence of different capsulorhexis sizes (including the diameter of the capsulorhexis, area of the anterior capsule opening, anterior capsule coverage, centration and circularity of the capsulorhexis) on the postoperative outcomes (eg, visual acuity, capsule shrinkage, IOL stability and intraocular pressure) in patients undergoing cataract surgery. This is particularly important in patients with high myopia or diabetes mellitus. The proposed protocol aims to enhance the transparency of our research and offer references for future studies.

View Article and Find Full Text PDF

Purpose: We report a novel technique which enables to cut any kind of foldable lens and extract it using capsulorhexis forceps and a 1.2 mm single-use slit angled knife.

Methods: The technique consists in using the capsulorhexis forceps to mantain and stabilize the IOL in the anterior chamber, and while one hand holds the IOL in that way, the second hand introduces a 1.

View Article and Find Full Text PDF

More attention should be paid to the deviations between the actual diameter of the rhexis reference circle which projected by the Image-guided systems and its intended size, and assess the influence of ocular biometric parameters on the deviation. In this study, the Callisto eye image-guided system was employed to generate a digital rhexis reference circle (rhexis overlay) set at an intended diameter of 6 mm and a screenshot of the video was taken at the end of the cataract surgery, then to compare the deviation between the observed rhexis overlay diameter (ROD) and the optic diameter (6 mm). The factors influencing diameter deviation were identified with univariate and multivariate linear regression.

View Article and Find Full Text PDF

Effects of capsulorhexis size and position on post-surgical IOL alignment.

Sci Rep

December 2024

Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.

In cataract surgery, post-surgical stability of the intraocular lens plays a major role. This study aims to explore how the size and decentration of the capsulorhexis affect intraocular lens decentration and tilt by using numerical methods. Finite element models included zonules, ciliary body, capsular bag, and an IOL with two open-loop haptics were built.

View Article and Find Full Text PDF

Unlabelled: The scientific and practical interest in studying the biomechanical characteristics of the lens capsule, on the one hand, is associated with its anatomical significance in modern microinvasive phaco surgery, and on the other hand, with investigation of the mechanisms of lens curvature changes during accommodation. Selective study of the biomechanical properties of the lens capsule aims to identify characteristics of various regions and surfaces of the capsule.

Purpose: This study is a comparative analysis of age-related changes in the biomechanical properties of the anterior (AC) and posterior (PC) lens capsules in humans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!