Subclinical leaflet thrombosis (SLT) is a potentially serious complication of aortic valve replacement with a bioprosthetic valve in which blood clots form on the replacement valve. SLT is associated with increased risk of transient ischemic attacks and strokes and can progress to clinical leaflet thrombosis. SLT following aortic valve replacement also may be related to subsequent structural valve deterioration, which can impair the durability of the valve replacement. Because of the difficulty in clinical imaging of SLT, models are needed to determine the mechanisms of SLT and could eventually predict which patients will develop SLT. To this end, we develop methods to simulate leaflet thrombosis that combine fluid-structure interaction and a simplified thrombosis model that allows for deposition along the moving leaflets. Additionally, this model can be adapted to model deposition or absorption along other moving boundaries. We present convergence results and quantify the model's ability to realize changes in valve opening and pressures. These new approaches are an important advancement in our tools for modeling thrombosis because they incorporate both adhesion to the surface of the moving leaflets and feedback to the fluid-structure interaction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691439PMC
http://dx.doi.org/10.1002/cnm.3700DOI Listing

Publication Analysis

Top Keywords

leaflet thrombosis
16
valve replacement
12
subclinical leaflet
8
thrombosis slt
8
aortic valve
8
fluid-structure interaction
8
moving leaflets
8
valve
7
thrombosis
6
slt
6

Similar Publications

Background: In the last years, the Cor-Knot device has been increasingly used in heart valve surgery. Our aim was to investigate the incidence of valvular complications in patients who underwent valvular surgery using the Cor-Knot device in multicentric cohorts at one-year follow-up.

Methods: Three hundred and sixty-eight patient underwent heart valve repair or replacement surgery using automated titanium suture fasteners in four cardiothoracic surgery departments between September 2018 and January 2020.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a well-established treatment for severe aortic stenosis, especially in patients over 75 or those at high surgical risk. While these prosthetic valves have a lower thrombogenic profile than mechanical heart valves, leaflet thrombosis in transcatheter aortic valves (TAV) occurs in an estimated 5%-40% of cases. Most TAV thromboses are subclinical and can be detected via cardiac computed tomography (CCT), which reveals hypo-attenuating leaflet thickening and reduced leaflet motion in asymptomatic patients without elevated transprosthetic gradients on echocardiography.

View Article and Find Full Text PDF

Leaflet thrombosis after transcatheter aortic valve replacement (TAVR) presents a significant challenge, leading to adverse clinical outcomes. Subclinical leaflet thrombosis (SLT) is increasingly recognized, and there is a growing concern about its role in clinical events and hemodynamic valve deterioration. Current recommendations for prophylactic anticoagulation or antiplatelet therapy following TAVR are primarily based on expert consensus rather than definitive evidence from randomized trials, resulting in a variety of antithrombotic strategies in clinical practice.

View Article and Find Full Text PDF

Background: The short-term and midterm impact of gender differences on transcatheter aortic valve implantation (TAVI) has been studied. However, the impact on long-term clinical outcomes remains unclear. The objective of the study was to investigate the impact of gender differences after TAVI on long-term clinical outcomes and structural valve deterioration (SVD).

View Article and Find Full Text PDF

The dark side of the fibroblastic sleeve: Case report and literature review.

J Vasc Access

December 2024

Clinical Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.

The fibroblastic sleeve is a structure potentially enveloping any intravascular device. At ultrasound scan, it typically presents as a thin layer of variably echogenic material covering the catheter surface, which usually tends to remain into the vessel after the catheter removal. However, several case reports have documented its migration toward the heart or pulmonary artery after a central venous catheter removal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!