Objective: The aim of this study was to determine the quality of fetal biometry and pulsed-wave Doppler ultrasound measurements in a prospective cohort study in Uganda.
Methods: This was an ancillary study of the Ending Preventable Stillbirths by Improving Diagnosis of Babies at Risk (EPID) project, in which women enroled in early pregnancy underwent Doppler and fetal biometric assessment at 32-40 weeks of gestation. Sonographers undertook 6 weeks of training followed by onsite refresher training and audit exercises. A total of 125 images for each of the umbilical artery (UA), fetal middle cerebral artery (MCA), left and right uterine arteries (UtA), head circumference (HC), abdominal circumference (AC) and femur length (FL) were selected randomly from the EPID study database and evaluated independently by two experts in a blinded fashion using objective scoring criteria. Inter-rater agreement was assessed using modified Fleiss' kappa for nominal variables and systematic errors were explored using quantile-quantile (Q-Q) plots.
Results: For Doppler measurements, 96.8% of the UA images, 84.8% of the MCA images and 93.6% of the right UtA images were classified as of acceptable quality by both reviewers. For fetal biometry, 96.0% of the HC images, 96.0% of the AC images and 88.0% of the FL images were considered acceptable by both reviewers. The kappa values for inter-rater reliability of quality assessment were 0.94 (95% CI, 0.87-0.99) for the UA, 0.71 (95% CI, 0.58-0.82) for the MCA, 0.87 (95% CI, 0.78-0.95) for the right UtA, 0.94 (95% CI, 0.87-0.98) for the HC, 0.93 (95% CI, 0.87-0.98) for the AC and 0.78 (95% CI, 0.66-0.88) for the FL measurements. The Q-Q plots indicated no influence of systematic bias in the measurements.
Conclusions: Training local healthcare providers to perform Doppler ultrasound, and implementing quality control systems and audits using objective scoring tools in clinical and research settings, is feasible in low- and middle-income countries. Although we did not assess the impact of in-service retraining offered to practitioners deviating from prescribed standards, such interventions should enhance the quality of ultrasound measurements and should be investigated in future studies. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/uog.26051 | DOI Listing |
Eur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Am Fam Physician
January 2025
University of Florida College of Medicine, Gainesville.
Jaundice is an indication of hyperbilirubinemia and is caused by derangements in bilirubin metabolism. It is typically apparent when serum bilirubin levels exceed 3 mg/dL and can indicate serious underlying disease of the liver or biliary tract. A comprehensive medical history, review of systems, and physical examination are essential for differentiating potential causes such as alcoholic liver disease, biliary strictures, choledocholithiasis, drug-induced liver injury, hemolysis, or hepatitis.
View Article and Find Full Text PDFJ Neurosurg
January 2025
1Department of Neurosurgery, St. Olav's University Hospital, Trondheim, Norway.
Objective: The extent of resection (EOR) and postoperative residual tumor (RT) volume are prognostic factors in glioblastoma. Calculations of EOR and RT rely on accurate tumor segmentations. Raidionics is an open-access software that enables automatic segmentation of preoperative and early postoperative glioblastoma using pretrained deep learning models.
View Article and Find Full Text PDFNeurol Neuroimmunol Neuroinflamm
March 2025
Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney.
Background And Objectives: Despite the absence of acute lesion activity in multiple sclerosis (MS), chronic neurodegeneration continues to progress, and a potential underlying mechanism could be the kynurenine pathway (KP). Prolonged activation of the KP from chronic inflammation is known to exacerbate the progression of neurodegenerative diseases through the production of neurotoxic metabolites. Among the 8 KP metabolites, six of them, namely kynurenine (KYN), 3-hydroxylkynurenine (3HK), anthranilic acid (AA), kynurenic acid (KYNA), and quinolinic acid (QUIN), have been associated with neurodegeneration.
View Article and Find Full Text PDFInvest Radiol
January 2025
From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).
Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!