Summary: The incidence of vascular occlusion injuries has risen substantially along with the increasing popularity of cosmetic injectables. Among these occurrences, instances of soft-tissue ischemic events following the injection of nonparticulate solutions, such as botulinum, represent an enigmatic etiology that has yet to be fully understood. One hypothesized mechanism of injury underlying these events relates to the accidental capture and intravascular ejection of needle microcores, defined as submillimeter tissue fragments trapped by the beveled lumen of a needle during conventional injections. To test this hypothesis, the authors conducted a cytologic evaluation of dermal remnants incidentally captured by 31-G tuberculin needles following repeated injections into postrhytidectomy skin fragments. Their findings revealed the presence of dermal tissue microcores ranging from 100 to 275 μm in diameter with an overall microcoring incidence of 0.7%. These findings confirm the ability of ultrafine needles, commonly used in botulinum injections, to produce tissue microcores that may serve as causative agents of vascular occlusion with nonparticulate solutions. Awareness of this mechanism of injury may be of benefit in the early recognition and management of these rare occurrences.

Clinical Question/level Of Evidence: Therapeutic, V.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PRS.0000000000010508DOI Listing

Publication Analysis

Top Keywords

needle microcores
8
vascular occlusion
8
nonparticulate solutions
8
mechanism injury
8
tissue microcores
8
microcores pose
4
pose occlusive
4
occlusive threat
4
threat nonparticulate
4
nonparticulate injections?
4

Similar Publications

Background And Objectives: Several types of needles are available for EUS-guided tissue sampling of pancreatic lesions. Whereas fine-needle aspiration (FNA) needles typically provide cytological samples, fine-needle biopsy (FNB) needles are designed to obtain microcores with preserved tissue architecture. The aim of this study was to compare tissue amount and diagnostic yield between a modified Franseen-type FNB needle (TopGain; Medi-Globe GmbH, Grassau, Germany) and a standard FNA needle.

View Article and Find Full Text PDF

Objectives: Compare the 22G needle versus EchoTip ProCore® 20 (Cook Medical, Bloomington, IN, USA) on their handling, specimen suitability, amount of tissue obtained, diagnostic performance, the possibility of immunohistochemistry, and rate of adverse events.

Materials And Methods: This is a retrospective, comparative study of consecutively examined patients with pancreatic masses who underwent endosonography-guided fine needle aspiration (FNA) via the 22G needle, and endosonography-guided tissue acquisition (TA) via ProCore 20 (PC20). The operator evaluated needle insertion and subjectively classified the specimen.

View Article and Find Full Text PDF

Summary: The incidence of vascular occlusion injuries has risen substantially along with the increasing popularity of cosmetic injectables. Among these occurrences, instances of soft-tissue ischemic events following the injection of nonparticulate solutions, such as botulinum, represent an enigmatic etiology that has yet to be fully understood. One hypothesized mechanism of injury underlying these events relates to the accidental capture and intravascular ejection of needle microcores, defined as submillimeter tissue fragments trapped by the beveled lumen of a needle during conventional injections.

View Article and Find Full Text PDF

While approximately 85% of neoplasms are ductal pancreatic adenocarcinomas (DPA), adenosquamous pancreatic carcinoma (APC) is a rare subtype of pancreatic cancer that exhibits aggressive behavior and poor prognosis. The authors report three cases of primary APC diagnosed through endoscopic ultrasound-guided tissue acquisition (EUS-TA) using the new ProCore 20G needle, which had been developed to improve fine-needle aspiration results by providing more tissue for histopathology. Given its ability for microcore retrieval, pancreatic stroma examination, and excellent histopathology results, EUS-TA has exhibited exceptional diagnostic yield among patients with solid pancreatic lesions.

View Article and Find Full Text PDF

Background: Innovative approaches to improve diagnostic yield of endoscopic ultrasound-guided tissue acquisition (EUS-TA) have focused on needle design with development of fine-needle biopsy (FNB) needles with microcore-acquisition technology. Recently, a 20-gauge (20G) antegrade-cutting-side-bevelled biopsy needle (ProCore®) was developed for EUS-TA, but data about its diagnostic performance and histological capability are scant.

Objectives: We assessed the diagnostic performance and histologic retrieval rate of a new 20G antegrade-cutting-side-bevelled biopsy needle compared with a 22G reverse-side-bevelled needle for EUS sampling of solid pancreatic lesions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!