Antegrade Flexible Nailing for Pediatric Metaphyseal-diaphyseal Junction Distal Radius Fracture, is it Safe?

Tech Hand Up Extrem Surg

Department of Orthopedic Surgery and Rehabilitation, Maimonides Medical Center, Brooklyn, New York, NY.

Published: September 2023

Fractures involving the distal radius metaphyseal-diaphyseal junction (MDJ) present a unique challenge for pediatric orthopedic surgeons. These fractures are too proximal for percutaneous K -wire fixation and too distal for retrograde flexible nailing. The purpose of this study was to: (1) determine the safety of a described antegrade approach from the posterior interosseous nerve (PIN); (2) assess the efficacy of antegrade nailing in cases of distal MDJ fractures; and (3) describe a standardized lateral approach to the proximal radius. A cadaveric study was performed using 10 adult forearms. Anterograde flexinail was introduced at the proximal radius based on the described "safe zone". Distal MDJ fractures were created using osteotomes. We evaluated the distance between the entry point to the PIN in addition to the quality of the reduction for the fracture. The average distance between the entry point and piercing instrument to the PIN was 5.4 cm (range: 4.7 to 6.0 cm). When grouped based on sex, the average distance was significantly further for males (5.8 cm, range: 5.2 to 6.0 cm) versus females (4.9 cm, range: 4.7 to 5.2 cm), P =0.004. Fracture reduction was not maintained after the introduction of the antegrade flexible nail across the fracture site. For all specimens, >25% displacement was seen on the anterior-posterior imaging. Our modified lateral approach to the starting point in the proximal radius is safe as long as the entry point for antegrade flexible nailing stays proximal to the radial tuberosity during the lateral approach to the proximal radius while the elbow is flexed and the forearm pronated.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BTH.0000000000000430DOI Listing

Publication Analysis

Top Keywords

proximal radius
16
antegrade flexible
12
flexible nailing
12
lateral approach
12
entry point
12
metaphyseal-diaphyseal junction
8
distal radius
8
distal mdj
8
mdj fractures
8
approach proximal
8

Similar Publications

Introduction: Although there is no consensus in the literature, it is believed that the Soong classification system and fracture pattern are risk factors for plate removal in distal radius fractures.

Hypothesis: The aim of this large-scale study was to evaluate the relationship between Soong classification, fracture pattern, and implant removal in distal radius fractures.

Materials And Methods: We retrospectively evaluated 795 patients who underwent surgery using a volar locking plate for distal radius fractures at our clinic between 2005 and 2022.

View Article and Find Full Text PDF

Introduction: Osteochondroma is a bony lesion arising from the surface of the bone. It com-prises a large percentage of all benign bone tumors. A unique feature of this tumor is the conti-nuity of cortical and medullary components between the normal bony tissue and aberrant tissue of osteochondroma.

View Article and Find Full Text PDF

Introduction: Giant cell tumour or osteoclastoma is benign, locally aggressive tumor with bone destruction and with malignant potential. It accounts for 5% of all primary bone tumor and occurs in skeletally mature individuals in the age group of 30 to 45 with peak incidence in the 3rd decade. GCT is more common in females.

View Article and Find Full Text PDF

Case: We present a 79-year-old woman with a complex elbow fracture including a comminuted proximal ulna fracture, coronoid process fracture, and comminuted radial head fracture treated with primary total elbow arthroplasty (TEA). The patient completed an early therapy protocol and had complete healing. At 15 months postoperatively, she had full pronosupination and elbow arc of motion from 10 to 135° with no reported pain.

View Article and Find Full Text PDF

Challenging management of multifocal upper extremity fractures in a polytrauma setting: A case report.

Int J Surg Case Rep

December 2024

Department of Orthopedics and Traumatology, Faculty of Medicine, Universitas Airlangga, East Java, Surabaya, Indonesia; Department Orthopedics and Traumatology, Dr. Soetomo General Academic Hospital, East Java, Surabaya, Indonesia. Electronic address:

Introduction And Importance: Multifocal fractures in a single upper extremity represent a significant clinical challenge, often resulting from high-energy impacts such as motor vehicle accidents or severe falls. These injuries require complex, multifaceted approaches in management, spanning initial acute care to long-term rehabilitation. This paper examines the complexities of diagnosing, treating, and rehabilitating multifocal upper extremity fractures, highlighting the importance of timely intervention and a multidisciplinary approach to maximize functional recovery, minimize long-term disability and the prognosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!