A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High Titer Antibodies Demonstrating Prozone in Two Repeat Blood Donors. | LitMetric

High Titer Antibodies Demonstrating Prozone in Two Repeat Blood Donors.

Indian J Hematol Blood Transfus

Department of Transfusion Medicine, Post Graduate Institute of Medical Education and Research, Sector 12, Chandigarh, India.

Published: April 2023

Introduction: - Prozone phenomenon due to excess unbound antibodies may sometimes lead to failure of detection of ABO incompatibility. . The case series describes immunohematology work up of blood group discrepancies of two blood donors.

Materials And Methods: - Blood grouping was performed by a fully automated immune hematology analyzer (FAIHA Diagast, Qwalys 3, France) based on the principle of erythrocyte magnetized technology. Further immunohematology workup was done by tube technique (at different temperatures and phases) and column agglutination technique (CAT). Antibody titration was done by tube technique at saline and AHG (anti human globulin) phase.

Results: - Type I blood group discrepancy was detected on initial blood grouping done by an automated analyzer. The discrepancy was resolved by repeat blood grouping by tube technique with a remarkable finding of hemolysis in reverse grouping. The lysis was attributed to high titer antibodies (anti-B titer of 512) with demonstration of prozone phenomenon. However, there was no discrepancy between cell and serum grouping by column agglutination technique (CAT).

Conclusion: - Tube technique is the gold standard method for blood grouping and detects blood group discrepancies optimally. Hemolysis which is taken as a positive result, can be best appreciated by tube technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064354PMC
http://dx.doi.org/10.1007/s12288-022-01583-5DOI Listing

Publication Analysis

Top Keywords

tube technique
20
blood grouping
16
blood group
12
blood
9
high titer
8
titer antibodies
8
repeat blood
8
prozone phenomenon
8
group discrepancies
8
column agglutination
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!