A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Determination of 12 typical personal care products in human urine samples by ultra performance liquid chromatography-tandem mass spectrometry]. | LitMetric

AI Article Synopsis

  • A new ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed to simultaneously detect 12 personal care products (PCPs) in human urine, focusing on paraben preservatives, benzophenone UV absorbers, and antibacterial agents.
  • The process included mixing urine samples with a buffer solution, followed by overnight enzymatic hydrolysis, and then using solid phase extraction and chromatographic separation for analysis.
  • The method showed high sensitivity with low detection limits (0.06-1.09 μg/L) and excellent linearity for most analytes, achieving correlation coefficients greater than 0.999.

Article Abstract

A rapid and sensitive method based on ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 12 typical personal care products (PCPs) in human urine. These PCPs included five paraben preservatives (PBs), five benzophenone UV absorbers (BPs), and two antibacterial agents. Accordingly, 1 mL of the urine sample was mixed with 500 μL of -glucuronidase-ammonium acetate buffer solution (enzymatic activities are 500 units/mL) and 75 μL of a mixed internal standard working solution (internal standard contents are 7.5 ng), followed by enzymatic hydrolysis overnight (≥16 h) at 37 ℃ in a water bath. The 12 targeted analytes were enriched and cleaned up using an Oasis HLB solid phase extraction column. Separation was performed on an Acquity BEH C column (100 mm×2.1 mm, 1.7 μm) using an acetonitrile-water system as the mobile phase, in negative electrospray ionization (ESI) multiple reaction monitoring (MRM) mode, for target detection and stable isotope internal standard quantification. The optimal MS conditions were established by optimizing the instrument parameters and comparing two analytical columns (Acquity BEH C and Acquity UPLC HSS T) as well as different types of mobile phases (methanol or acetonitrile as the organic phase) to achieve better chromatographic separation. In order to obtain higher enzymatic and extraction efficiency, different enzymatic conditions, solid phase extraction columns, and elution conditions were investigated. The final results showed that methyl parabens (MeP), benzophenone-3 (BP-3), and triclosan (TCS) showed good linearities in the ranges of 4.00-800, 4.00-800 and 5.00-200 μg/L, respectively, the other targeted compounds showed good linearities in the ranges of 1.00-200 μg/L. The correlation coefficients were all greater than 0.999. The method detection limits (MDLs) were in the range of 0.06-1.09 μg/L, and the method quantification limits (MQLs) ranged from 0.08 to 3.63 μg/L. At three spiked levels, the average recoveries of the 12 targeted analytes ranged from 89.5% to 111.8%. The intra-day and inter-day precisions were 3.7%-8.9% and 2.0%-10.6%, respectively. The results of the matrix effect assessment showed that MeP, ethyl paraben (EtP), and benzophenone-2 (BP-2) exhibited strong matrix effects (26.7%-103.8%); propyl paraben (PrP) exhibited moderate matrix effects (79.2%-112.0%); and the other eight target analytes exhibited weak matrix effects (83.3%-113.8%). The matrix effects of the 12 targeted analytes after correction using the stable isotopic internal standard method ranged from 91.9% to 110.1%. The developed method was successfully applied to the determination of the 12 PCPs in 127 urine samples. Ten typical PCPs were detected, with the overall detection rates ranging from 1.7% to 99.7%, except for benzyl paraben (BzP) and benzophenone-8 (BP-8). The results revealed that the population in this area was widely exposed to PCPs, especially MeP, EtP and PrP; the detection rates and concentrations of these PCPs were found to be very high. Our analytical method is simple and sensitive, and it is expected to be an effective tool for biomonitoring PCPs in human urine samples as part of environmental health studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10071352PMC
http://dx.doi.org/10.3724/SP.J.1123.2022.05032DOI Listing

Publication Analysis

Top Keywords

internal standard
16
matrix effects
16
human urine
12
urine samples
12
targeted analytes
12
typical personal
8
personal care
8
care products
8
ultra performance
8
performance liquid
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!