AI Article Synopsis

  • The study looked at patients who had surgery to fix loose parts in their elbows, finding out how often they needed to have surgery again afterward.
  • Researchers thought that changing the sizes of the elbow implants would help keep them stable better than just changing one part.
  • They found that about 25% of patients needed more surgery after an average of 4.2 years, and people with rheumatoid arthritis were more likely to need it again.

Article Abstract

Background: This study aimed to determine the re-revision rate in a cohort of patients who underwent revision total elbow arthroplasty (rTEA) for humeral loosening (HL) and identify factors contributing to re-revision. We hypothesized that proportional increases in the stem and flange lengths would stabilize the bone-implant interface significantly more than a disproportional increase in stem or flange length alone. Additionally, we hypothesized that the indication for the index arthroplasty would impact the need for repeated revision for HL. The secondary objective was to describe the functional outcomes, complications, and presence of radiographic loosening after rTEA.

Methods: We retrospectively reviewed 181 rTEAs performed from 2000-2021. We included 40 rTEAs for HL performed on 40 elbows that either required a subsequent revision for HL (10 rTEAs) or had a minimum of 2 years of clinical or radiographic follow-up. One hundred thirty-one cases were excluded. Patients were grouped based on stem and flange length to determine the re-revision rate. Patients were divided based on re-revision status into the single-revision group and the re-revision group. The stem-to-flange length (S/F) ratio was calculated for each surgical procedure. The mean length of clinical and radiographic follow-up was 71 months (range, 18-221 months and 3-221 months, respectively).

Results: Rheumatoid arthritis was statistically significant in predicting re-revision total elbow arthroplasty for HL (P = .024). The overall re-revision rate for HL was 25% at an average of 4.2 years (range, 1-19 years) from the revision procedure. There was a significant increase in stem and flange lengths from the index procedure to revision, on average by 70 ± 47 mm (P < .001) and 28 ± 39 mm (P < .001), respectively. In the cases of re-revision (n = 10), 4 patients underwent an excisional procedure; in the remaining 6 cases, the size of the re-revision implant increased on average by 37 ± 40 mm for the stem and 73 ± 70 mm for the flange (P = .075 and P = .046, respectively). Furthermore, the average flange in these 6 cases was 7 times shorter than the average stem (S/F ratio, 6.7 ± 2.2). This ratio was significantly different from that in cases that were not re-revised (P = .03; S/F ratio, 4.2 ± 2). Mean range of moion was 16° (range, 0°-90°; standard deviation, 20°) extension to 119° (range, 0°-160°; standard deviation, 39°) flexion at final follow-up. Complications included ulnar neuropathy (38%), radial neuropathy (10%), infection (14%), ulnar loosening (14%), and fracture (14%). None of the elbows were considered radiographically loose at final follow-up.

Conclusion: We show that a primary diagnosis of rheumatoid arthritis and a humeral stem with a relatively short flange relative to the stem length significantly contribute to re-revision of total elbow arthroplasty. The use of an implant where the flange can be extended beyond one-fourth of the stem length may increase implant longevity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2023.03.003DOI Listing

Publication Analysis

Top Keywords

stem flange
16
total elbow
12
re-revision rate
12
repeated revision
8
humeral loosening
8
revision total
8
determine re-revision
8
elbow arthroplasty
8
flange lengths
8
increase stem
8

Similar Publications

Improper osteotomy during total knee arthroplasty (TKA) can lead to anterior femoral notching, which increases the risk of periprosthetic fractures due to stress concentration. One potential solution is the addition of an intramedullary stem to the femoral component. However, the optimal stem length remains unclear.

View Article and Find Full Text PDF

What factors can reduce the need for repeated revision for humeral loosening in revision total elbow arthroplasty?

J Shoulder Elbow Surg

July 2023

Morsani College of Medicine, University of South Florida, Tampa, FL, USA; Florida Orthopaedic Institute (FOI), Tampa, FL, USA. Electronic address:

Article Synopsis
  • The study looked at patients who had surgery to fix loose parts in their elbows, finding out how often they needed to have surgery again afterward.
  • Researchers thought that changing the sizes of the elbow implants would help keep them stable better than just changing one part.
  • They found that about 25% of patients needed more surgery after an average of 4.2 years, and people with rheumatoid arthritis were more likely to need it again.
View Article and Find Full Text PDF

Effective masking policies to prevent the spread of airborne infections depend on public access to masks with high filtration efficacy. However, poor face-fit is almost universally present in pleated multilayer disposable face masks, severely limiting both individual and community respiratory protection. We developed a set of simple mask modifications to mass-manufactured disposable masks, the most common type of mask used by the public, that dramatically improves both their personalized fit and performance in a low-cost and scalable manner.

View Article and Find Full Text PDF

[Humeral bone defects in revision shoulder arthroplasty].

Orthopadie (Heidelb)

February 2023

Klinik für Orthopädie, Unfallchirurgie, Schulter- und Ellenbogenchirurgie und Endoprothetik, Rhön-Klinikum, Campus Bad Neustadt/Saale, Salzburger Leite 1, 97616, Bad Neustadt/Saale, Deutschland.

Background: Revision shoulder arthroplasty is mainly performed with reverse TSA and should consider proper adjustment of the length and the amount of bone loss in humeral reconstruction. Whilst epi-/metaphyseal bone loss can mostly be compensated easily by stemmed standard implants, advanced bone loss exceeding 2° requires the support of longer revision stems.

Extensive Humeral Bone Loss: Cementless fixation in the intact diaphyseal humerus is recommended in bone loss exceeding 2°, preferably with modular revision systems, because cemented reverse revision stems have higher loosening rates in the mid to long-term follow-up.

View Article and Find Full Text PDF

Attachment to the intestinal epithelium is critical to the lifestyle of the ubiquitous parasite Giardia lamblia. The ventrolateral flange is a sheet-like membrane protrusion at the interface between parasites and attached surfaces. This structure has been implicated in attachment, but its role has been poorly defined.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!