Using a contralateral shoe lift to reduce gait deterioration during an offloading fast-walk setting in diabetic peripheral neuropathy: A comparative feasibility study.

Diabetes Res Clin Pract

Department of Human Kinetics and Podiatric Medicine, Université du Québec à Trois-Rivières, 3351, boul. des Forges, C.P. 500, Trois-Rivières G9A 5H7, Canada; Centre de recherche du Centre intégré de santé et services sociaux de Chaudière-Appalaches (CISSS-CA), 143 rue Wolfe, Lévis G6V 3Z1, Canada; VITAM - Sustainable Health Research Centre, 2480, Rue de la Carnardière, Québec G1J 2G1, Canada. Electronic address:

Published: May 2023

Aims: Diabetic peripheral neuropathy (DPN) is a predictor of foot ulcers and leads to sedentary behaviour. This comparative study evaluated gait and feasibility of a 20-minute fast walk, at 40-60% of cardiopulmonary capacity, in individuals with DPN wearing an offloading boot and a contralateral shoe balancer.

Methods: Gait parameters were measured with inertial sensors on 32 individuals (group with DPN [n = 16], group with diabetes but without DPN [n = 9], and a group without diabetes/DPN [n = 7]). Feasibility was assessed by feedback on perceived effort and adverse events. Gait outcomes were compared between groups with or without a shoe balancer using one-way ANOVAs.

Results: The three groups were equivalent in terms of activity level and age and gender except for the body mass index. Both groups with diabetes exhibited minimal decreased gait speed (p > 0.005) and the DPN group exhibited increased double-support percentage (+4.6%, p = 0.01) while walking with an offloading boot and contralateral shoe balancer. The use of a contralateral shoe balancer reduced gait asymmetry. Lower physical activity level was associated with further gait deterioration in all groups. Few adverse events were reported, and 91% of participants reported that the proposed activity would be feasible daily.

Conclusions: The offloading boot deteriorated gait function, but a contralateral shoe balancer minimized its impact, especially in the context of physical activity in people with diabetes and DPN.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diabres.2023.110647DOI Listing

Publication Analysis

Top Keywords

contralateral shoe
20
shoe balancer
16
offloading boot
12
gait
8
gait deterioration
8
diabetic peripheral
8
peripheral neuropathy
8
boot contralateral
8
diabetes dpn
8
adverse events
8

Similar Publications

Background: This study investigated the effect of various offloading devices commonly used for the management of diabetic foot ulcerations on peak plantar pressure and pressure-time integral of the contralateral limb.

Methods: A quantitative, randomised and within-subject repeated measures study was conducted in an outpatient gait laboratory. Outpatients with unilateral diabetic foot ulcers and adequate perfusion to the lower limb without an intrinsic limb-length discrepancy who were able to walk were recruited for the study.

View Article and Find Full Text PDF

: To evaluate the clinical efficacy of combining an offloading device with a contralateral shoe lift to compensate for induced limb-length discrepancies in participants with plantar diabetes-related foot ulcers. : Between March 2021 and December 2023, 42 consecutive patients with active plantar diabetic foot ulcers (DFUs) were randomly assigned (1:1) to the treatment group (limb-length discrepancy compensation with a shoe lift in the therapeutic footwear of the contralateral limb) or a control group that did not receive limb-length discrepancy compensation. Primary outcomes included the 20-week wound-healing rate and wound area reduction.

View Article and Find Full Text PDF

Post traumatic lymphedema (PTL) is a known complication of extremity trauma that is detrimental to limb form and function, healing, and quality of life. In cases of complex lower extremity trauma with vascular and extensive soft tissue injury, the risk of PTL is increased. However, many trauma patients are lost to follow-up, making the risk and potential management of these patients' lymphedema difficult to characterize.

View Article and Find Full Text PDF

Research investigating ankle function during walking in a controlled ankle motion (CAM) boot has either placed markers on the outside of the boot or made major alterations to the structure of the CAM boot to uncover key landmarks. The aim of this study was to quantify joint kinematics and kinetics using "in-boot" skin markers whilst making only minimal structural alterations. Seventeen healthy participants walked at their preferred walking speed in two conditions: (1) in standard athletic trainers (ASICS patriot 8, ASICS Oceania Pty Ltd, USA), and (2) using a hard-cased CAM boot (Rebound® Air Walker, Össur, Iceland) fitted on the right foot.

View Article and Find Full Text PDF

Introduction: Controlled ankle motion (CAM) boots are a below-knee orthotic device prescribed for the management of foot and ankle injuries to reduce ankle range of motion (RoM) and offload the foot and ankle whilst allowing continued ambulation during recovery. There is a lack of clarity within the current literature surrounding the biomechanical understanding and effectiveness of CAM boots.

Aims: To summarise the biomechanical effects of CAM boot wear as an orthotic for restricting ankle RoM and offloading the foot.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!