Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The free peroneal artery perforator (FPAP) flap is used for soft tissue defects after burns and trauma. However, the use of FPAP flaps to repair limb soft tissue defects for immediate reconstruction was rarely reported previously. Therefore, the purpose of this report is to evaluate free peroneal artery perforator flap to reconstruct traumatic limb soft tissue defects for immediate reconstruction.
Patients And Methods: A total of 25 cases of limb soft tissue defects undergoing immediate reconstruction of FPAP flap transfer were retrospectively evaluated from January 2019 to June 2019 in our institute. The locations of defects included the palm (10 cases), finger (5 cases), foot (7 cases), ankle (2 cases) and wrist (1 case). The sizes of defect varied from 3 × 2 cm to 15 × 7 cm (54.1 cm in average). Flaps were harvested based on the peroneal perforator vessels, initially marked using hand-held Doppler.
Results: Average size of harvested flap was 9.7 × 6.2 cm (ranging from 3.5 × 2 cm to 16 × 8 cm). All perforators were harvested from the peroneal artery and the arterial diameter ranged from 0.8 to 1.7 mm. The average pedicle length was 3.04 cm (range, 1.85-4.75 cm). Five vascular thrombosis were found including three cases of arterial thrombosis and two cases of venous thrombosis which were successfully salvaged by re-operation and vein graft. Satisfying functional outcome and acceptable appearance were achieved at 6 months or longer after surgery (range, 6-15 months, 12 months in average). All flaps survived at the end-point.
Conclusions: The FPAP flap is a reliable and thin fasciocutaneous flap, which can be used for repairing limb soft tissue defects. The FPAP flap can be used for covering defects with various appearances, locations, and sizes.