Orbital blowout fractures are peculiar injuries causing disruption of both ocular function and symmetry. We present our experience with the use of a precontoured titanium mesh in orbital blowout fractures. A retrospective study of patients undergoing correction of orbital blowout fractures with a precontoured titanium mesh was done at a tertiary care center in Mumbai. Data regarding demographics and pre- and postoperative clinical and radiological attributes were retrieved and compared. A total of 21 patients (19 males and 2 females) underwent correction of blowout fractures with a precontoured titanium mesh. The follow-up period ranged from 6 to 10 months. Road traffic accident (76%) was the most common etiology. Twenty (95%) patients had impure blowout fractures and 1 (5%) patient had a pure blowout. The orbital floor was most commonly fractured (16 [76%]). Associated fractures of the zygomaticomaxillary complex were found in 71% of patients. All patients were operated on within 3 weeks of trauma. A comparison of the operated and uninjured sides on coronal views of computed tomography (CT) scan in nine patients by Photopea application revealed a correction of the increased cross-sectional area in all cases. Enophthalmos was completely corrected in 94% patients, while 92% patients had complete correction of diplopia. One patient with a comminuted zygomatic fracture had persistent diplopia and mild enophthalmos. Infraorbital paresthesia persisted in 58% patients at 6 months of follow-up. No significant postoperative complications were noted. The precontoured titanium mesh restores orbital wall anatomy and is safe, quick, fairly easy, and reproducible with a shorter learning curve. With proper patient selection and execution, prefabricated titanium mesh can serve as an excellent reconstructive option in blowout fractures of the orbit.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10049819 | PMC |
http://dx.doi.org/10.1055/s-0043-1761597 | DOI Listing |
Clin Ophthalmol
January 2025
Retina Service, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.
Purpose Of Review: Intimate partner violence (IPV) is a leading cause of death and disability across the world. We sought to investigate the prevalence and clinical presentation of ocular injuries in IPV.
Recent Findings: Literature review revealed 16 published studies that evaluated ocular injuries in IPV, of which the study types included 9 retrospective studies, 2 prospective, 1 review, 1 invited commentary, 2 case reports, and 1 population-based cross-sectional survey.
Sci Rep
January 2025
Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
This study aims to evaluate and compare the usability and performance of mixed reality (MR) technology versus conventional methods for preoperative planning of patient-specific reconstruction plates for orbital fractures. A crossover study design was used to compare MR technology with conventional three-dimensional (3D) printing approaches in the planning of maxillofacial traumatology treatments. The primary focus was on user-friendliness and the accuracy of patient-specific reconstruction planning.
View Article and Find Full Text PDFJ Stomatol Oral Maxillofac Surg
January 2025
Dept of Oral & Maxillofacial Surgery, Faculty of Dentistry, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia. Electronic address:
Introduction: Orbital fractures are common among maxillofacial injuries. The primary objective of this study was to investigate the clinical and radiographic characteristics of pure orbital blowout fractures (OBFs) and their association with post-traumatic diplopia. The secondary objective was to identify predictors of diplopia in pure OBFs.
View Article and Find Full Text PDFCureus
December 2024
Department of Ophthalmology, Sir Takhtasinhji General Hospital, Bhavnagar, IND.
Traumatic optic neuropathy (TON) is a rare condition resulting from damage to the optic nerve due to craniofacial trauma. It can present as direct or indirect injuries, with mechanisms ranging from mechanical disruption by fractures in direct TON to transmitted forces causing shearing and ischemia in indirect TON. These injuries often lead to significant visual impairment or complete vision loss, requiring timely diagnosis and intervention.
View Article and Find Full Text PDFGraefes Arch Clin Exp Ophthalmol
January 2025
Department of Oculoplastic, Orbital & Lacrimal Surgery, Aichi Medical University Hospital, 1-1 Yazako-Karimata, Nagakute, Aichi, 480-1195, Japan.
Purpose: To define the anatomical variance between orbital floor and medial orbital wall blowout fractures, and its change with age.
Methods: This was a retrospective, observational study analyzing data from 557 patients with isolated blowout fractures of the orbital floor or medial orbital wall. Axial and quasi-sagittal CT images were analyzed to compare radiologic data on orbital wall morphology between fracture site groups and among age groups.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!