. The mechanical behaviour of soft tissue is influenced by its elastic and viscous characteristics. Therefore, the aim of this study was to develop a validated method to characterise the viscoelastic properties of soft tissues based on ultrasound elastography data.. Plantar soft tissue was chosen as the tissue of interest, and gelatine-phantoms replicating its mechanical properties were manufactured for validation of the protocol. Both plantar soft tissue and the phantom were scanned using Reverberant shear wave ultrasound (US) elastography at 400-600 Hz. Shear wave speed was estimated using the US particle velocity data. The viscoelastic parameters were extracted by fitting the Young's modulus as a function of frequency derived from the constitutive equations of the eight rheological models (four classic and their fractional-derivative versions) to the shear wave dispersion data. Furthermore, stress-time functions derived from the eight rheological models were fitted to the phantom stress-relaxation data.. The viscoelastic parameters estimated using elastography data based on the fractional-derivative (FD) models, compared to the classic models, were closer to those quantified using the mechanical test. In addition, the FD-Maxwell and FD-Kelvin-Voigt models showed to more effectively replicate the viscoelastic behaviour of the plantar soft tissue with minimum number of model parameters (R2= 0.72 for both models) . Hence the FD-KV and FD-Maxwell models can more effectively quantify the viscoelastic characteristics of the soft tissue compared to other models.. In this study, a method for mechanical characterisation of the viscoelastic properties of soft tissue in ultrasound elastography was developed and fully validated. An investigation into the most valid rheological model and its applications in plantar soft tissue assessment were also presented. This proposed approach for the characterisation of viscous and elastic mechanical properties of soft tissue has implications in assessing the soft tissue function where those can be used as markers for diagnosis or prognosis of tissue status.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/acc923DOI Listing

Publication Analysis

Top Keywords

soft tissue
44
plantar soft
20
ultrasound elastography
16
tissue
13
rheological models
12
properties soft
12
shear wave
12
soft
11
models
9
viscous elastic
8

Similar Publications

Background: Transperitoneal approach to robot-assisted pyeloplasty (RAP) have been preferred in the last decades because of the use of multi-port robotic platforms. However, this approach is linked to notable issues, such as pneumoperitoneum and lateral decubitus position, which is associated with potential soft tissues injuries, and it is a time-consuming procedure. Single-port (SP) platform was introduced to potentially address these issues.

View Article and Find Full Text PDF

Objective: Systematic review of literature on the pre-clinical studies of dental implantation in different models by finding out data about primary stability.

Materials And Methods: PubMed, NCBI, Wiley Online Library, MBPI, Elibrary systems were used for search.

Results: Based on the literature review of the described animal species dogs have the most similar bone structure to humans but their usage is complicated by ethics and law reasons.

View Article and Find Full Text PDF

The Study Aims: To evaluate and compare the growth of gingiva around dental implants following the use of collagen matrices and connective tissue grafts (CTG).

Materials And Methods: The study included 80 study participants, who were divided into four groups based on the type of material used to enhance gingival thickness. Two groups utilized collagen matrices, Fibro-Gide and FibroMatrix as materials, while the other two groups utilized CTG obtained from the hard palate or tubercle area of the maxilla as controls.

View Article and Find Full Text PDF

A 56-year-old male smoker presented to the Emergency Department with a painful mass in the left ischiorectal fossa, which had been present for 2 months without any other symptoms. On examination, a hard, violet-colored mass was observed, with an ulcerated central area. Blood tests were normal, and the abdominal-pelvic CT scan showed multiple hypervascular intra-abdominal masses and soft tissue lesions.

View Article and Find Full Text PDF

Introduction: Clubfoot is at times associated with other lower extremity abnormalities, such as leg length discrepancy (LLD). Initial studies in patients treated with extensive soft tissue release (STR) have estimated that LLD is prevalent in 9% to 11% of children with idiopathic clubfoot. However, Ponseti-style serial casting has since replaced STR as the preferred clubfoot treatment method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!