Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Pressure coupled with shear stresses are the critical external factors for diabetic foot ulceration assessment and prevention. To date, a wearable system capable of measuring in-shoe multi-directional stresses for out-of-lab analysis has been elusive. The lack of an insole system capable of measuring plantar pressure and shear hinders the development of an effective foot ulcer prevention solution that could be potentially used in a daily living environment. This study reports the development of a first-of-its-kind sensorised insole system and its evaluation in laboratory settings and on human participants, indicating its potential as a wearable technology to be used in real-world applications. Laboratory evaluation revealed that the linearity error and accuracy error of the sensorised insole system were up to 3% and 5%, respectively. When evaluated on a healthy participant, change in footwear resulted in approximately 20%, 75% and 82% change in pressure, medial-lateral and anterior-posterior shear stress, respectively. When evaluated on diabetic participants, no notable difference in peak plantar pressure, as a result of wearing the sensorised insole, was measured. The preliminary results showed that the performance of the sensorised insole system is comparable to previously reported research devices. The system has adequate sensitivity to assist footwear assessment relevant to foot ulcer prevention and is safe to use for people with diabetes. The reported insole system presents the potential to help assess diabetic foot ulceration risk in a daily living environment underpinned by wearable pressure and shear sensing technologies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10056665 | PMC |
http://dx.doi.org/10.3390/s23063126 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!