Purpose: To compare the effects of deep learning reconstruction (DLR) on respiratory-triggered T2-weighted MRI of the liver between single-shot fast spin-echo (SSFSE) and fast spin-echo (FSE) sequences.
Methods: Respiratory-triggered fat-suppressed liver T2-weighted MRI was obtained with the FSE and SSFSE sequences at the same spatial resolution in 55 patients. Conventional reconstruction (CR) and DLR were applied to each sequence, and the SNR and liver-to-lesion contrast were measured on FSE-CR, FSE-DLR, SSFSE-CR, and SSFSE-DLR images. Image quality was independently assessed by three radiologists. The results of the qualitative and quantitative analyses were compared among the four types of images using repeated-measures analysis of variance or Friedman's test for normally and non-normally distributed data, respectively, and a visual grading characteristics (VGC) analysis was performed to evaluate the image quality improvement by DLR on the FSE and SSFSE sequences.
Results: The liver SNR was lowest on SSFSE-CR and highest on FSE-DLR and SSFSE-DLR (P < 0.01). The liver-to-lesion contrast did not differ significantly among the four types of images. Qualitatively, noise scores were worst on SSFSE-CR but best on SSFSE-DLR because DLR significantly reduced noise (P < 0.01). In contrast, artifact scores were worst both on FSE-CR and FSE-DLR (P < 0.01) because DLR did not reduce the artifacts. Lesion conspicuity was significantly improved by DLR compared with CR in the SSFSE (P < 0.01) but not in FSE sequences for all readers. Overall image quality was significantly improved by DLR compared with CR for all readers in the SSFSE (P < 0.01) but only one reader in the FSE (P < 0.01). The mean area under the VGC curve values for the FSE-DLR and SSFSE-DLR sequences were 0.65 and 0.94, respectively.
Conclusion: In liver T2-weighted MRI, DLR produced more marked improvements in image quality in SSFSE than in FSE.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11024712 | PMC |
http://dx.doi.org/10.2463/mrms.mp.2022-0111 | DOI Listing |
Am J Sports Med
January 2025
Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, California, USA.
Background: Anterior cruciate ligament (ACL) injury often leads to posttraumatic osteoarthritis (PTOA), despite ACL reconstruction (ACLR). Medial meniscal extrusion (MME) is implicated in PTOA progression but remains understudied after ACL injury and ACLR.
Hypothesis/purpose: It was hypothesized that MME would increase longitudinally after ACL injury and ACLR, with greater changes in the ipsilateral knee compared with the contralateral knee, leading to cartilage degeneration.
J Orthop Traumatol
December 2024
Sapienza Universitiy, Rome, Italy.
Introduction: The plantar plate, also called the plantar ligament, is a fibrocartilaginous structure found in the metatarsophalangeal (MTP) and interphalangeal (IP) joints. Our study aimed to evaluate the role of magnetic resonance imaging (MRI) performed with the patient in the standard position or with joint hyperextension (the "stress test", ST) in the study of plantar plate (PP) disease that involves metatarsophalangeal joints.
Materials And Methods: All patients underwent forefoot MRI (Atroscan C, Esaote, Genoa, Italy), operating at 0.
Radiology
December 2024
From the Department of Radiology, Hanyang University Hospital, 222-1 Wangsimni-ro, Seongdong-gu, Seoul 04763, South Korea (Sunmin Lee, Y.J.K., Seunghun Lee); Department of Radiology, Hanyang University Guri Hospital, Guri, South Korea (J.R.); Department of Radiology, Eunpyeong St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea (H.Y.L.); Department of Radiology, University of California, Davis, Sacramento, Calif (H.J.); Biostatistics Laboratory, Medical Research Collaborating Center, Industry-University Cooperation Foundation, Hanyang University, Seoul, South Korea (H.W.T., J.K.); and Department of Pre-Medicine, College of Medicine, Hanyang University, Seoul, South Korea (J.K.).
Background The calcified cartilage layer and subchondral bone plate (SBP) contribute to osteoarthritis development. Three-dimensional (3D) ultrashort echo-time (UTE) MRI can help to evaluate calcified cartilage and SBP in various stages of cartilage degradation. Purpose To compare calcified cartilage and SBP abnormalities using 3D UTE MRI with cartilage degradation and osteochondral junction (OCJ) abnormalities observed at proton-density fast spin-echo with fat suppression (PDFS) MRI.
View Article and Find Full Text PDFHeliyon
November 2024
Department of Physics, Toronto Metropolitan University, 350 Victoria Street, Toronto, ON, Canada.
Magn Reson Imaging
February 2025
Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing 102218, China. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!