Background: Commissural alignment has become an important topic in transcatheter aortic valve replacement (TAVR) because it may improve coronary access, facilitate future valve procedures, and possibly improve valve durability. The efficacy of commissural alignment with ACURATE neo2 has not yet been shown in a large population.

Objectives: The authors sought to determine the feasibility and success of attempting commissural alignment in an unselected TAVR population treated with the ACURATE neo2 prosthetic heart valve.

Methods: A total of 170 consecutive patients underwent TAVR with a dedicated implantation technique to align the TAVR valve to the native valve. Using right-left overlap and 3-cusp views, valve orientation was adjusted by rotation of the unexpanded valve at the level of the aortic root. Effectiveness was assessed postprocedure as the degree of misalignment determined by analyzing fluoroscopic valve orientation to corresponding cusp orientation on preprocedural computed tomography. Safety endpoints included mortality, stroke/transient ischemic attack, and additional complications through 30 days.

Results: Of 170 patients, 167 (98.2%) could be analyzed for alignment, and all 170, for safety outcomes. Most patients (97%) had successful alignment (≤ mild misalignment), with 80% with commissural alignment, while the degrees of misalignment were 17% mild, 1.2% moderate, 1.8% severe.

Conclusions: In this large evaluation of a commissural alignment technique, alignment was achieved in nearly all patients without safety concerns or impact to procedure duration. Commissural alignment appears effective and safe across all patients with this novel technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2023.01.018DOI Listing

Publication Analysis

Top Keywords

commissural alignment
28
acurate neo2
12
valve
9
alignment
9
alignment acurate
8
valve orientation
8
commissural
7
patients
5
neo2 valve
4
valve unselected
4

Similar Publications

Brain color-coded diffusion imaging: Utility of ACPC reorientation of gradients in healthy subjects and patients.

Comput Methods Programs Biomed

December 2024

Université Clermont Auvergne, CNRS, CHU Clermont-Ferrand, Clermont Auvergne INP, Institut Pascal, F-63000 Clermont-Ferrand, France; Université Clermont Auvergne, Clermont Auvergne INP, CNRS, Institut Pascal, F-63000 Clermont-Ferrand, France. Electronic address:

Background And Objective: The common structural interpretation of diffusion color-encoded (DCE) maps assumes that the brain is aligned with the gradients of the MRI machine. This is seldom achieved in the field, leading to incorrect red (R), green (G) and blue (B) DCE values for the expected orientation of fiber bundles. We studied the virtual reorientation of gradients according to the anterior commissure - posterior commissure (ACPC) system on the RGB derivatives.

View Article and Find Full Text PDF

We present one of the inaugural transcatheter aortic valve implantation procedures using the latest Medtronic platform, Evolut FX+. Successful coronary angiography was achieved within 28 seconds and 1 minute 49 seconds for the left and right coronary arteries, respectively. Postoperative cardiac computed tomography scan demonstrated optimal commissural and diamond-coronary alignment.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the hemodynamic effects of commissural alignment (CA) in patients receiving self-expandable transcatheter aortic valves (TAVR) using two different devices: Evolut Pro (EP) and Acurate neo2 (AN2).
  • Analyzing 557 patients, the results showed that CA was linked to a significant reduction in the rate of commissural misalignment (CMA) compared to those without CA, leading to lower transvalvular gradients and less aortic regurgitation after one year.
  • Although patients with moderate/severe CMA experienced worsened aortic gradients and regurgitation rates, overall structural deterioration criteria were not met at
View Article and Find Full Text PDF
Article Synopsis
  • Patients with severe aortic stenosis often have coronary artery disease (CAD), and how to manage this condition during transcatheter aortic valve implantation (TAVI) is still debated.
  • This review discusses the timing of coronary revascularization strategies—whether to perform percutaneous coronary intervention (PCI) before, during, or after TAVI—and the expected increase in PCI procedures as more low-risk patients are referred for TAVI.
  • Expert opinions suggest that there may be a shift towards performing PCI after TAVI, supported by studies on TAVI's safety in patients with untreated CAD and advancements in implantation techniques that enhance access to coronary arteries post-procedure.
View Article and Find Full Text PDF
Article Synopsis
  • Coronary access (CA) and percutaneous coronary intervention (PCI) can be more difficult after valve-in-valve transcatheter aortic valve replacement (ViV-TAVR), especially with certain valve designs.* -
  • A study found that the ACURATE neo2 valve led to significantly better success rates for both CA (96.7%) and PCI (98.3%) compared to the Evolut PRO+ valve (75% and 85%, respectively).* -
  • The design differences between the valves affected procedural approaches, with ACURATE neo2 allowing for easier access due to a greater valve-to-anatomy distance.*
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!