Background: Commissural alignment has become an important topic in transcatheter aortic valve replacement (TAVR) because it may improve coronary access, facilitate future valve procedures, and possibly improve valve durability. The efficacy of commissural alignment with ACURATE neo2 has not yet been shown in a large population.
Objectives: The authors sought to determine the feasibility and success of attempting commissural alignment in an unselected TAVR population treated with the ACURATE neo2 prosthetic heart valve.
Methods: A total of 170 consecutive patients underwent TAVR with a dedicated implantation technique to align the TAVR valve to the native valve. Using right-left overlap and 3-cusp views, valve orientation was adjusted by rotation of the unexpanded valve at the level of the aortic root. Effectiveness was assessed postprocedure as the degree of misalignment determined by analyzing fluoroscopic valve orientation to corresponding cusp orientation on preprocedural computed tomography. Safety endpoints included mortality, stroke/transient ischemic attack, and additional complications through 30 days.
Results: Of 170 patients, 167 (98.2%) could be analyzed for alignment, and all 170, for safety outcomes. Most patients (97%) had successful alignment (≤ mild misalignment), with 80% with commissural alignment, while the degrees of misalignment were 17% mild, 1.2% moderate, 1.8% severe.
Conclusions: In this large evaluation of a commissural alignment technique, alignment was achieved in nearly all patients without safety concerns or impact to procedure duration. Commissural alignment appears effective and safe across all patients with this novel technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcin.2023.01.018 | DOI Listing |
Comput Methods Programs Biomed
December 2024
Université Clermont Auvergne, CNRS, CHU Clermont-Ferrand, Clermont Auvergne INP, Institut Pascal, F-63000 Clermont-Ferrand, France; Université Clermont Auvergne, Clermont Auvergne INP, CNRS, Institut Pascal, F-63000 Clermont-Ferrand, France. Electronic address:
Background And Objective: The common structural interpretation of diffusion color-encoded (DCE) maps assumes that the brain is aligned with the gradients of the MRI machine. This is seldom achieved in the field, leading to incorrect red (R), green (G) and blue (B) DCE values for the expected orientation of fiber bundles. We studied the virtual reorientation of gradients according to the anterior commissure - posterior commissure (ACPC) system on the RGB derivatives.
View Article and Find Full Text PDFJACC Case Rep
September 2024
Department of Cardiology, Houston Methodist DeBakey Heart and Vascular Center, Houston, Texas, USA.
We present one of the inaugural transcatheter aortic valve implantation procedures using the latest Medtronic platform, Evolut FX+. Successful coronary angiography was achieved within 28 seconds and 1 minute 49 seconds for the left and right coronary arteries, respectively. Postoperative cardiac computed tomography scan demonstrated optimal commissural and diamond-coronary alignment.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
November 2024
Cardiology Department, University Clinic Hospital, Valladolid, Spain.
Expert Rev Med Devices
October 2024
Department of Medicine and Surgery, Università degli Studi di Enna "Kore", Enna, Italy.
Can J Cardiol
November 2024
Jagiellonian University Medical College, Krakow, Poland.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!