To evaluate the Misonix bone scalpel (MBS) for craniotomies in dogs and describe clinical findings and surgical experience in 3 dogs with large multilobular osteochondrosarcoma (MLO) of the skull. Cadaver evaluation and retrospective case series. One canine cadaver; 3 client-owned dogs. Craniotomies of different sizes and at different locations were performed with MBS. Dural tear and bone discoloration were recorded. Clinical, imaging, and surgical findings of dogs diagnosed with MLO and where MBS was used for craniectomies were retrospectively included. Cadaveric evaluation identified MBS as an efficient tool for rapid craniectomies (>5minutes) albeit dural tears and some small foci of bone discoloration were observed. Craniectomies could be performed without complications in 3 dogs with MLO without dural tear or bone discoloration. .Excision was in complete in all cases. The short-term outcome was good, and the long-term outcome was fair to good. Piezoelectric bone surgery with the Misonix bone scalpel is an alternative technology to perform craniectomies in dogs. It was not associated with complications in 3 dogs diagnosed and surgically treated for MLO. Dural tears and suspected bone necrosis can occur. Great care should be taken when using CT to establish disease free surgical osteotomy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.tcam.2023.100772DOI Listing

Publication Analysis

Top Keywords

misonix bone
12
bone scalpel
12
bone discoloration
12
craniectomies dogs
8
multilobular osteochondrosarcoma
8
bone
8
cadaveric evaluation
8
evaluation retrospective
8
retrospective case
8
case series
8

Similar Publications

Background Context: Cage subsidence is a complication of interbody fusion associated with poor clinical outcomes. 3D-printed titanium interbody cages allow for the alteration of features such as stiffness and porosity. However, the influence of these features on subsidence and their biological effects on fusion have not been rigorously evaluated.

View Article and Find Full Text PDF

Shortening Dome Osteotomy for the Correction of Coronal Plane Elbow Deformities.

JBJS Essent Surg Tech

October 2024

Department of Orthopaedic Surgery, Lok Nayak Hospital, Maulana Azad Medical College, New Delhi, India.

Background: Severe elbow deformities are common in developing countries because of neglect or as a result of prior treatment that achieved poor reduction. Various osteotomy techniques have been defined for the surgical correction of elbow deformities. However, severe elbow deformities (>30°) pose a substantial challenge for surgeons because limited surgical options with high complication rates have been described in the literature.

View Article and Find Full Text PDF
Article Synopsis
  • The study introduces a new rib-sparing technique for thoracic corpectomy, which minimizes post-operative complications associated with rib removal during spinal surgery.
  • Researchers conducted a chart review of 36 corpectomies performed on 32 patients from 2015 to 2023, noting key metrics like estimated blood loss and operative time.
  • Results showed the technique was effective, with an average post-operative stay of 6.5 days, highlighting the advantages of using an ultrasonic bone scalpel for this procedure.
View Article and Find Full Text PDF

Objective: To report a digital workflow for use and long-term outcome of cranioplasty with a 3D-printed patient-specific Polyetheretherketone (PEEK) implant in a 12-y-old German Shepherd dog after surgical removal of an extensive occipital bone multilobular osteochondrosarcoma (MLO).

Study Design: Retrospective case report.

Animal: A 12-year-old neutered female German Shepherd dog was presented with facial deformity, blindness, tetraparesis, and ataxia.

View Article and Find Full Text PDF

Study Design: Retrospective analysis of a prospective, multicenter registry.

Objective: To assess whether upper or lower limb mJOA improvement more strongly associates with patient satisfaction after surgery for cervical spondylotic myelopathy (CSM).

Summary Of Background Data: The modified Japanese Orthopaedic Association (mJOA) is commonly used to assess functional status in patients with CSM.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!