A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a novel Ultra Performance Liquid Chromatography Tandem-Mass Spectrometry (UPLC-MS/MS) method to measure l-arginine metabolites in plasma. | LitMetric

Introduction: Arginine metabolism is involved in the regulation of several biological processes. Many liquid chromatography tandem-mass spectrometry methods for the determination of arginine and its metabolites have been developed but they are time consuming and imply long pre-analytical procedures. The purpose of this study was to develop a rapid method for the simultaneous determination of arginine, citrulline, ornithine, symmetric and asymmetric dimethylarginine and monomethylarginine in human plasma.

Materials And Methods: The pre-analytical procedure consisted in a simple deproteinization. The chromatographic separation was performed using hydrophilic interaction liquid chromatography. Analytes detection was performed with a triple quadrupole equipped with electrospray ion source operating in positive ion mode. Mass spectrometry experiments were conducted in multiple reaction monitoring mode.

Results And Conclusions: Recovery ranged from 92.2 to 108.0%. The within-run imprecision and between-run imprecision ranged from 1.5 to 6.8 % and 3.8 to 11.9%, respectively. Carry over and matrix effect did not affect quantitative analysis. Extraction recovery was between 95 and 105 %. Stability after pre-analytical procedure was tested and all the metabolites were stable after 48 h at 4 °C. In conclusion, our novel method allow a rapid and easy determination of arginine and its metabolites both for research and clinical routine use.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2023.117306DOI Listing

Publication Analysis

Top Keywords

liquid chromatography
12
determination arginine
12
chromatography tandem-mass
8
tandem-mass spectrometry
8
arginine metabolites
8
pre-analytical procedure
8
development novel
4
novel ultra
4
ultra performance
4
performance liquid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!