While thrombosis is the leading cause of morbidity and mortality in the United States, an understanding of its triggers, progression, and response to anticoagulant therapy is lacking. Intravital fluorescence microscopy has advanced the study of thrombus formation by providing targeted, multi-color contrast. However, photodegradation of fluorophores limits the application in longitudinal studies (e.g., clot progression and/or dissolution). Fluorescent nanodiamond (FND) is a fluorophore which utilizes intrinsic fluorescence of chromogenic centers within and protected by the diamond crystalline lattice. Recent developments in diamond processing have allowed for the controlled production of nanodiamonds emitting in green or red. Here, the use of FND to label blood clots and/or clot lysis is demonstrated and compared to commonly used organic fluorophores. Model ex vivo clots were formed with incorporated labeled fibrinogen to allow imaging. FND was shown to match the morphology of organic fluorophore labels absent of photobleaching over time. The addition of tissue plasminogen activator (tPa) allowed visualization of the clot lysis stage, which is vital to studies of both DVT and pulmonary embolism resolution.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10055895 | PMC |
http://dx.doi.org/10.3390/nano13060961 | DOI Listing |
Thromb Haemost
January 2025
Department of Medicine, Jagiellonian University School of Medicine, Cracow, Poland.
Background: Asthma is associated with a prothrombotic state. Plasma factor VIIa-antithrombin complex concentrations (FVIIa-AT) indirectly reflect the interaction of tissue factor (TF) with FVII. Since TF is a key initiator of coagulation in vivo, we hypothesized that FVIIa-AT are higher in asthma.
View Article and Find Full Text PDFMacromol Biosci
January 2025
Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Carrer de Baldiri Reixac, 10, 12, Barcelona, 08028, Spain.
Blood-contacting medical devices, especially extracorporeal membrane oxygenators (ECMOs), are highly susceptible to surface-induced coagulation because of their extensive surface area. This can compromise device functionality and lead to life-threatening complications. High doses of anticoagulants, combined with anti-thrombogenic surface coatings, are typically employed to mitigate this risk, but such treatment can lead to hemorrhagic complications.
View Article and Find Full Text PDFChronic inflammation and heme-iron overload can result from bacterial hemolysis. Along with the synthetic drugs, numerous traditional and functional food approaches are equally trialed to eradicate the problem. As a prospective new source of dietary protein hydrolysates, freshwater mollusks () have recently drawn huge interest from researchers.
View Article and Find Full Text PDFThromb Haemost
January 2025
Department of Medical Physiology, Hamamatsu University School of Medicine, Hamamatsu, Japan.
Background: Fibrinolysis is spatiotemporally well-regulated and greatly influenced by activated platelets and coagulation activity. Our previous real-time imaging analyses revealed that clotting commences on activated platelet surfaces, resulting in uneven-density fibrin structures, and that fibrinolysis initiates in dense fibrin regions and extends to the periphery. Despite the widespread clinical use of direct oral anticoagulants (DOACs), their impact on thrombin-dependent activation of thrombin-activatable fibrinolysis inhibitor (TAFI) and fibrinolysis remains unclear.
View Article and Find Full Text PDFJ Avian Med Surg
January 2025
Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA.
Viscoelastic testing evaluates the formation and lysis of a clot over time, allowing more complete assessment of patient hemostasis in real time, whereas traditional tests, such as prothrombin time and partial thromboplastin time, only measure coagulation factor function. Patient-side viscoelastic coagulation monitors are easy to use, portable, and provide faster turnaround time than commercial laboratories. Viscoelastic testing requires only 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!