AI Article Synopsis

Article Abstract

In high-power laser systems, the primary cause of contamination of optical components and degradation of spatial cleanliness is laser-induced sputtering of particles. To mitigate this problem, laminar flow is frequently utilized to control the direction and transport of these particles. This study characterizes the properties of laser-induced sputtering particles, including their flying trend, diameter range, and velocity distribution at varying time intervals. A time-resolved imaging method was employed to damage the rear surface of fused silica using a 355 nm Nd: YAG pump laser. The efficacy of laminar flow in controlling these particles was then assessed, with a particular focus on the influence of laminar flow direction, laminar flow velocity, particle flight height, and particle diameter. Our results indicate that the optimal laminar flow velocity for preventing particle invasion is highly dependent on the maximum particle attenuation distance (or safety distance), which can vary by up to two orders of magnitude. Furthermore, a laminar flow velocity of 0.5 m/s can effectively prevent particle sedimentation. Future research will aim to optimize laminar flow systems based on these findings to achieve high surface cleanliness in high-power laser systems with minimal energy consumption.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10051549PMC
http://dx.doi.org/10.3390/mi14030598DOI Listing

Publication Analysis

Top Keywords

laminar flow
32
laser-induced sputtering
12
sputtering particles
12
high-power laser
12
laser systems
12
flow velocity
12
surface cleanliness
8
laminar
8
flow
8
particles
5

Similar Publications

Microfluidic chips are powerful tools for investigating numerous variables including chemical and physical parameters on protein aggregation. This study investigated the aggregation of bovine serum albumin (BSA) in two different systems: a vial-based static system and a microfluidic chip-based dynamic system in which BSA aggregation was induced successfully. BSA aggregation induced in a microfluidic chip on a timescale of seconds enabled a dynamic investigation of the forces driving the aggregation process.

View Article and Find Full Text PDF

Optic Nerve Head Changes in Acute Central Serous Chorioretinopathy: Implications for Glaucoma Risk.

Photodiagnosis Photodyn Ther

January 2025

Istanbul Medeniyet University, Faculty of Medicine, Department of Ophthalmology, Istanbul, Turkey. Electronic address:

Objective: Imaging techniques have demonstrated changes in the choroid and retina in acute central serous chorioretinopathy (CSCR), but the effects on the optic nerve head (ONH) remain unclear. This study investigates ONH structural changes in acute CSCR using enhanced deep imaging optic coherence tomography (EDI-OCT).

Methods: A prospective cohort study included 51 acute CSCR patients and 51 healthy controls aged 18-65 years.

View Article and Find Full Text PDF

The droplet dynamics of asymmetrical impingement on moving ridged surface.

J Colloid Interface Sci

January 2025

School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093 China. Electronic address:

Hypothesis: The depth of research into the mechanism of droplet impacting structured surfaces dictates the efficacy of their applications. The impact stress generated when a droplet impacts a surface is a pivotal factor influencing the efficiency of surface applications, ultimately determining the extent of surface wear. Despite the systematic examination of impact force, there remains a scarcity of research on impact stress and its mitigation strategies.

View Article and Find Full Text PDF

The galvanic corrosion and electrical insulation between TC4 Ti-alloy and 304 stainless steel coupled in pipe joints were investigated using the finite element method. The results obtained from polarization were applied as boundary conditions. The simulation incorporated secondary current distribution with chemical species transport and laminar flow.

View Article and Find Full Text PDF

Designing Microfluidic-Chip Filtration with Multiple Channel Networks for the Highly Efficient Sorting of Cell Particles.

Micromachines (Basel)

December 2024

Complex Fluids Laboratory, Advanced Materials and Systems Research Division, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea.

Microfluidic-chip based hydrodynamic filtration is one of the passive sorting techniques that can separate cell or particle suspensions into subpopulations of different sizes. As the branch channels and side channels play an important role in maintaining particle focusing, their rational design is necessary for highly efficient sorting. A model framework involving multiple side and multiple branch channels has been developed by extending the analytical analysis of three-dimensional laminar flow in channel networks, which was previously validated by comparison with numerical simulations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!