A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Value of Left Ventricular Mechanical Dyssynchrony and Scar Burden in the Combined Assessment of Factors Associated with Cardiac Resynchronization Therapy Response in Patients with CRT-D. | LitMetric

Background: Cardiac resynchronization therapy (CRT) improves the outcome in patients with heart failure (HF). However, approximately 30% of patients are nonresponsive to CRT. The aim of this study was to determine the role of the left ventricular (LV) mechanical dyssynchrony (MD) and scar burden as predictors of CRT response.

Methods: In this study, we included 56 patients with HF and the left bundle-branch block with QRS duration ≥ 150 ms who underwent CRT-D implantation. In addition to a full examination, myocardial perfusion imaging and gated blood-pool single-photon emission computed tomography were performed. Patients were grouped based on the response to CRT assessed via echocardiography (decrease in LV end-systolic volume ≥15% or/and improvement in the LV ejection fraction ≥5%).

Results: In total, 45 patients (80.3%) were responders and 11 (19.7%) were nonresponders to CRT. In multivariate logistic regression, LV anterior-wall standard deviation (adjusted odds ratio (OR) 1.5275; 95% confidence interval (CI) 1.1472-2.0340; = 0.0037), summed rest score (OR 0.7299; 95% CI 0.5627-0.9469; = 0.0178), and HF nonischemic etiology (OR 20.1425; 95% CI 1.2719-318.9961; = 0.0331) were the independent predictors of CRT response.

Conclusion: Scar burden and MD assessed using cardiac scintigraphy are associated with response to CRT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10059815PMC
http://dx.doi.org/10.3390/jcm12062120DOI Listing

Publication Analysis

Top Keywords

scar burden
12
left ventricular
8
ventricular mechanical
8
mechanical dyssynchrony
8
dyssynchrony scar
8
cardiac resynchronization
8
resynchronization therapy
8
predictors crt
8
response crt
8
crt
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!