The Mini-Balance Evaluation Systems Test (Mini-BESTest), a 14-item scale, has high content validity for balance assessment. This study further examines the construct validity of the Mini-BESTest with an emphasis on its measurement invariance. The Mini-BESTest was administered to 292 neurological patients in two sessions (before and after rehabilitation) and evaluated with the Rasch analysis (Many-Facet Rating Scale Model: persons, items, sessions). Categories' order and fit to the model were assessed. Next, maps, dimensionality, and differential item functioning (DIF) were examined for construct validity evaluation. DIF was inspected for several clinically important variables, including session, diagnosis, and assistive devices. Mini-BESTest items had ordered categories and fitted the Rasch model. The item map did not flag severe construct underrepresentation. The dimensionality analysis showed that another variable extraneous to balance affected the score of a few items. However, this multidimensionality had only a modest impact on measures. Session did not cause DIF. DIF for assistive devices affected six items and caused a severe measurement artefact. The measurement artefact caused by DIF for diagnosis was negligible. The Mini-BESTest returns interval measures with robust construct validity and measurement invariance. However, caution should be used when comparing Mini-BESTest measures obtained with and without assistive devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10049698PMC
http://dx.doi.org/10.3390/ijerph20065166DOI Listing

Publication Analysis

Top Keywords

construct validity
12
assistive devices
12
differential item
8
item functioning
8
rasch analysis
8
measurement invariance
8
measurement artefact
8
mini-bestest
7
dif
5
functioning mini-bestest
4

Similar Publications

The recovery of valuable materials from spent lithium-ion batteries (LIBs) has experienced increasing demand in recent years. Current recycling technologies are typically energy-intensive and are often plagued by high operation costs, low processing efficiency, and environmental pollution concerns. In this study, an efficient and environmentally friendly dielectrophoresis (DEP)-based approach is proposed to separate the main components of "black mass" mixtures from LIBs, specifically lithium iron phosphate (LFP) and graphite, based on their polarizability differences.

View Article and Find Full Text PDF

Background And Purpose: To develop a new test to assess the motor coordination of the upper limbs, and to investigate the test-retest and inter-rater reliability, construct validity, standard error of measurement (SEM), minimum detectable change (MDC), and the reference values.

Methods: The Upper Extremity Motor Coordination Test (UEMOCOT)was applied for 20 s, with the individual touching two targets (one right and one left) as quickly as possible, first with the hand (manual task) and then with the index finger (finger task). To test-retest reliability, the UEMOCOT was administered two times.

View Article and Find Full Text PDF

The Nurse Practitioner Holistic Caring Instrument (NPHCI) is a 19-item, investigator-developed instrument designed to measure holistic caring in nurse practitioner (NP) practice. This paper evaluates multi-sample psychometric testing of the instrument, describing data from three samples, with analysis supporting the NPHCI as a valid and reliable instrument. Methods: The NPHCI has been administered in patient, NP program faculty, and NP convenience samples.

View Article and Find Full Text PDF

Application of the SpCas9 inhibitor BRD0539 for CRISPR/Cas9-based genetic tools in .

Biosci Microbiota Food Health

September 2024

Department of Agricultural Chemistry, Graduate School of Tokyo University of Agriculture, 1-1-1 Sakuragaoka, Setagaya-ku, Tokyo 156-8502, Japan.

Although the clustered regularly interspaced short palindromic repeat (CRISPR)-Cas system has been extensively developed since its discovery for eukaryotic and prokaryotic genome editing and other genetic manipulations, there are still areas warranting improvement, especially regarding bacteria. In this study, BRD0539, a small-molecule inhibitor of Cas9 (SpCas9), was used to suppress the activity of the nuclease during genetic modification of , as well as to regulate CRISPR interference (CRISPRi). First, we developed and validated a CRISPR-SpCas9 system targeting the gene of .

View Article and Find Full Text PDF

Objective: To establish and validate a model based on hyperdense middle cerebral artery sign (HMCAS) radiomics features for predicting hemorrhagic transformation (HT) in patients with acute ischemic stroke (AIS) after endovascular treatment (EVT).

Methods: Patients with AIS who presented with HMCAS on non-contrast computed tomography (NCCT) at admission and underwent EVT at three comprehensive hospitals between June 2020 and January 2024 were recruited for this retrospective study. A radiomics model was constructed using the HMCAS radiomics features most strongly associated with HT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!