A sensitive and selective label-free photoelectrochemical (PEC) immunosensor was designed for the detection of cardiac troponin I (cTnI). The platform was based on a fluorine-doped tin oxide (FTO)-coated glass photoelectrode modified with bismuth vanadate (BiVO) and sensitized by an electrodeposited bismuth sulfide (BiS) film. The PEC response of the BiS/BiVO/FTO platform for the ascorbic acid (AA) donor molecule was approximately 1.6-fold higher than the response observed in the absence of BiS. The cTnI antibodies (anti-cTnI) were immobilized on the BiS/BiVO/FTO platform surface to produce the anti-cTnI/BiS/BiVO/FTO immunosensor, which was incubated in cTnI solution to inhibit the AA photocurrent. The photocurrent obtained by the proposed immunosensor presented a linear relationship with the logarithm of the cTnI concentration, ranging from 1 pg mL to 1000 ng mL. The immunosensor was successfully employed in artificial blood plasma samples for the detection of cTnI, with recovery values ranging from 98.0% to 98.5%.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10046628PMC
http://dx.doi.org/10.3390/bios13030379DOI Listing

Publication Analysis

Top Keywords

cardiac troponin
8
bis film
8
fluorine-doped tin
8
tin oxide
8
bis/bivo/fto platform
8
ctni
5
photoelectrochemical determination
4
determination cardiac
4
troponin biomarker
4
biomarker myocardial
4

Similar Publications

Background: A 63-year-old Black woman presented with progressive exertional dyspnea and chronic lower back pain. The course and findings in her case are instructive.

Case Report: Family history was notable for cardiac deaths.

View Article and Find Full Text PDF

Background: Qi Li Qiang Xin (QLQX) capsule has a solid theoretical basis and clinical efficacy in the treatment of chronic heart failure; however, the underlying mechanisms remain obscure. This study was designed to determine the effect of the QLQX on the treatment of heart failure and delineate the underlying mechanisms via a nontargeted metabolomics and lipidomics approach.

Methods: A rat model of heart failure after myocardial infarction (MI) was established via permanent ligation of the anterior descending branch of the left coronary artery.

View Article and Find Full Text PDF

Authors' response to commentary on: Prognostic value of cardiac troponin in elderly patients with paroxysmal supraventricular tachycardia: A multicenter study.

Am J Emerg Med

December 2024

Department of Emergency Medicine, Chang Gung Memorial Hospital, Linkou Branch, Taoyuan, Taiwan; Department of Emergency Medicine, New Taipei Municipal Tucheng Hospital, New Taipei City, Taiwan; Institute of Emergency and Critical Care Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan. Electronic address:

View Article and Find Full Text PDF

Surface-enhanced Raman spectroscopy for the characterization of filtrate portions of blood serum samples of myocardial infarction patients using 30 kDa centrifugal filter devices.

Spectrochim Acta A Mol Biomol Spectrosc

December 2024

Department of Chemistry, Institut - Courtois, Quebec Center for Advanced Materials (QCAM), and Regroupement Québécois sur les Matériaux de Pointe (RQMP), Université de Montréal, Montréal, Quebec H3C 3J7, Canada.

Myocardial infarction (MI) is the leading cause of death and disability worldwide. It occurs when a thrombus forms after an atherosclerotic plaque bursts, obstructing blood flow to the heart. Prompt and accurate diagnosis is crucial for improving patient survival.

View Article and Find Full Text PDF

Implementation of a High-sensitivity Troponin Assay for Adult Patients Who Present to the Emergency Department With Chest Pain: The Role of Clinical Decision Support.

CJC Open

December 2024

Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, College of Health Sciences, University of Alberta, Edmonton, Alberta, Canada.

Background: The objective of this study was to assess the health outcomes for patients who present to the emergency department (ED) with cardiac chest pain after the implementation of an accelerated diagnostic protocol using a high-sensitivity troponin assay (hs-TnI).

Methods: This prospective before-after cohort study used population-based linked health administrative data for adult patients who presented to a Canadian urban ED with chest pain of suspected cardiac origin over a 2-year study period. The primary outcome was ED length of stay (LOS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!