Background: A semiconductor rectal probe was used to compare planned and measured rectal doses during Co-60 high dose rate (HDR) CT-based intracavitary brachytherapy applications (ICBT) of cervical cancer.
Materials And Methods: A total of 22 HDR brachytherapy applications were included from 11 patients who were first treated with EBRT to the whole pelvis with a total prescribed dose of 50 Gy in 25 fractions. During each application, a PTW 9112 probe rectal probe having a series of five semiconductor diodes (R1 to R5) was inserted into the patient's rectum and a CT-based HDR ICBT application with a prescribed dose per fraction of 7 or 7.5 Gy to HRCTV was performed. Measurements were carried in water phantom using PTW rectal and universal adaptor plugs. Doses measured in phantom and with patients were compared to those calculated by the treatment planning system.
Results: The mean percentage dose difference ΔD (%) between calculated and measured values from phantom study were -5.29%, 1.89%, -2.72%, -4.76, and 0.72% for R1, R2, R3, R4, and R3 diodes, respectively and the overall mean ΔD (%) value with standard deviation (SD) was -2.03%±9.6%. From the patient study, a ΔD (%) that ranged from -19.5% to 24.0%, which corresponded to dose disparities between -0.77 Gy and 0.66 Gy. The median ΔD (%) ranged from 0.4% to 1.3%, or -0.03 to 0.05 Gy, respectively. ΔD (%) values exceeded 10% in approximately 26.4% of measurements (29 out of 110 in 22 applications). The location of Rmax in computed and measured values differs in 5 of 22 applications might be due to possible displacement of rectal probe between simulation and treatment.
Conclusion: Despite the likely geometrical shift of measuring detectors between insertion and treatment, in-vivo dosimetry is feasible and can be used to estimate the dose to the rectum during HDR ICBT.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10334100 | PMC |
http://dx.doi.org/10.31557/APJCP.2023.24.3.897 | DOI Listing |
Materials (Basel)
January 2025
Radiochemical Studies Laboratory, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Center for Scientific Research "Demokritos", Patriarchou Grigoriou and 27 Neapoleos Street, 15341 Athens, Greece.
Due to their intriguing emission profile, Terbium-161 (Tb) radiopharmaceuticals seem to bring significant advancement in theranostic applications to cancer treatment. The combination of Tb with nanoscale brachytherapy as an approach for cancer treatment is particularly advantageous and promising. Herein, we propose the application of a hybrid nanosystem comprising gold decorated (Au@TADOTAGA) iron oxide nanoflowers as a form of injectable nanobrachytherapy for the local treatment of breast cancer.
View Article and Find Full Text PDFBiomedicines
January 2025
Doctoral Studies Department, Biomedical Science, 410087 Oradea, Romania.
Cervical cancer is the most important cancer type found in women throughout the world. Numerous research studies are being performed to investigate the effectiveness of different strategies for the imaging and treatment of locally advanced cervical cancer, which are showing favorable outcomes. Brachytherapy is characterized by the application of very high radiation doses to target tumor cells with the least exposure to normal tissues.
View Article and Find Full Text PDFTech Innov Patient Support Radiat Oncol
March 2025
Mount Vernon Cancer Centre, Northwood, United Kingdom.
Brachytherapy is a key treatment for gynaecological malignancies, delivering high doses to the tumour volume whilst sparing nearby normal tissues due to its steep dose gradient. Accuracy is imperative as small shifts can lead to clinically significant under- or over-dosing of the target volume or organs at risk (OARs), respectively. Independent verification of dose delivered during brachytherapy is not routinely performed but it is important to identify gross errors and define action thresholds to guide inter-fraction treatment decisions.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
January 2025
McGill university, Montreal, Qc, Canada.
Purpose: High dose rate (HDR) prostate brachytherapy (BT) procedure requires image-guided needle insertion. Given that general anesthesia is often employed during the procedure, minimizing overall planning time is crucial. In this study, we explore the clinical feasibility and time-saving potential of artificial intelligence (AI)-driven auto-reconstruction of transperineal needles in the context of US-guided prostate BT planning.
View Article and Find Full Text PDFBrachytherapy
January 2025
Department of Genitourinary Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX.
Background: To determine outcomes of MRI-assisted radiosurgery (MARS) for salvage brachytherapy using the radioisotope Pd after various upfront treatments including surgery, external beam radiotherapy, and brachytherapy.
Methods: We retrospectively reviewed data for patients who underwent salvage MARS for intraprostatic lesions or prostate bed recurrences from 2016 to 2022. Biochemical recurrence, prostate cancer-specific, and overall survival, and the cumulative incidences of toxicities, were determined by Kaplan-Meier estimates.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!