Due to wavelength-specific water absorption, infrared lasers like the thulium laser emitting at 1940 nm wavelength proved to be suitable for coagulation in neurosurgery. Commonly bipolar forceps used for intraoperative haemostasis can cause mechanical and thermal tissue damage, whilst thulium laser can provide a tissue-gentle haemostasis through non-contact coagulation. The aim of this work is a less-damaging blood vessel coagulation by pulsed thulium laser radiation in comparison to standard bipolar forceps haemostasis. Ex vivo porcine blood vessels in brain tissue (0.34 ± 0.20 mm diameter) were irradiated in non-contact with a thulium laser in pulsed mode (1940 nm wavelength, 15 W power, 100-500 ms pulse duration), with a CO gas flow provided simultaneously at the distal fibre tip (5 L/min). In comparison, a bipolar forceps was used at various power levels (20-60 W). Tissue coagulation and ablation were evaluated by white light images and vessel occlusion was visualised by optical coherence tomography (OCT) B-scans at a wavelength of 1060 nm. Coagulation efficiency was calculated by means of the quotient of the difference between the coagulation and ablation radius to the coagulation radius. Pulsed laser application achieved blood vessel occlusion rate of 92% at low pulse duration of 200 ms with no occurrence of ablation (coagulation efficiency 100%). Bipolar forceps showed an occlusion rate of 100%, however resulted in tissue ablation. Tissue ablation depth with laser application is limited to 40 μm and by a factor of 10 less traumatising than with bipolar forceps. Pulsed thulium laser radiation achieved blood vessel haemostasis up to 0.3 mm in diameter without tissue ablation and has proven to be a tissue-gentle method compared to bipolar forceps.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10042905PMC
http://dx.doi.org/10.1007/s10103-023-03747-9DOI Listing

Publication Analysis

Top Keywords

bipolar forceps
28
thulium laser
24
blood vessel
16
pulsed thulium
12
tissue ablation
12
laser
8
vessel haemostasis
8
1940 nm wavelength
8
coagulation
8
laser radiation
8

Similar Publications

The surgical management of hepatic metastases from colorectal cancer may range from segmental resections to major or extended hepatectomies. The aim is to achieve complete removal of metastatic lesions while preserving adequate liver function. We present the case of a 42-year-old male patient with a history of glucose intolerance who presented with altered bowel movements and abdominal pain.

View Article and Find Full Text PDF

Alterations in white matter microstructure in bipolar disorder patients with and without psychosis.

Prog Neuropsychopharmacol Biol Psychiatry

December 2024

Department of Nuclear Medicine, West China Hospital of Sichuan University, Chengdu, China; Research Unit of Psychoradiology, Chinese Academy of Medical Sciences, Chengdu, China. Electronic address:

Objective: The overlap of affective disturbance and psychosis considerably makes it complex to determine the etiology of bipolar disorder (BD) and develop targeted interventions. The present study aimed to determine the white matter microstructural alterations that distinguish between BD with psychosis (BDP) and BD with no psychosis (BDNP) to identify patients who may specifically benefit from appropriately effective treatments.

Methods: Diffusion-weighted magnetic resonance images were acquired from 38 participants with BDP, 52 participants with BDNP and 70 healthy controls (HCs).

View Article and Find Full Text PDF

The Senhance robotic system (Asensus Surgical, Durham, NC, USA) is an innovative platform for minimally invasive surgery. It enables surgeons to perform precise and cost-effective procedures using reusable instruments and has advanced features such as haptic feedback and eye-tracking camera control. Herein, we present the first application of the "double bipolar method" (DBM) in a Senhance-assisted laparoscopic partial cystectomy utilizing 3 mm Maryland bipolar instruments.

View Article and Find Full Text PDF

Study Objective: To determine the association of repeat polypectomy with patient and/or polyp characteristics, surgical setting, and type of hysteroscopic equipment.

Methods: Retrospective cohort study including all women who had undergone operative hysteroscopy for the removal of endometrial polyps between 1/2012-12/2022 in our division. Operative hysteroscopy with resection of endometrial polyps was performed using a bipolar loop resectoscope, miniaturized hysteroscopic instruments (bipolar needle, scissors, and graspers), or a tissue-removal device (from April 2021), with or without general anesthesia.

View Article and Find Full Text PDF

Introduction: The three-arm approach is mainly selected, despite the multiple robotic arms in da Vinci Xi. This type of surgical setup may provide less autonomy to the console surgeon and result in greater dependence on the bedside surgical assistant. Therefore, the 4th arm is used instead of the assist port, which is why we developed "pure" robot simple hysterectomy (PRSH) as a novel surgical technique, in which all ports are operated by robotic arms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!