Sensitivity and Specificity of MRI versus CBCT to Detect Vertical Root Fractures Using MicroCT as a Reference Standard.

J Endod

Division of TMD and Orofacial Pain, School of Dentistry, University of Minnesota, Minneapolis, Minnesota; Departments of Radiology & Neurology, Medical School, University of Minnesota, Minneapolis, Minnesota.

Published: June 2023

Introduction: Vertical root fracture (VRF) in root-canal-treated teeth frequently results in tooth loss, partly because VRFs are difficult to diagnose and when detected the fracture is often beyond the point of preservation with surgical intervention. Nonionizing magnetic resonance imaging (MRI) has demonstrated the ability to detect small VRFs, but it is unknown how its diagnostic capabilities compare with the current imaging standard for VRF detection, cone-beam computed tomography (CBCT). This investigation aimed to compare the sensitivity and specificity between MRI and CBCT for detecting VRF, using micro-computed tomography (microCT) as a reference.

Methods: A total of 120 extracted human tooth roots were root canal treated using common techniques, and VRFs were mechanically induced in a proportion. Samples were imaged using MRI, CBCT, and microCT. Axial MRI and CBCT images were examined by 3 board-certified endodontists, who evaluated VRF status (yes/no) and gave a confidence assessment for that decision, from which a receiver operating characteristic curve was generated. Intra- and inter-rater reliability were calculated, sensitivity and specificity, and area under the curve.

Results: Intra-rater reliability was 0.29-0.48 for MRI and 0.30-0.44 for CBCT. Inter-rater reliability for MRI was 0.37 and for CBCT 0.49. Sensitivity was 0.66 (95% confidence interval [CI], 0.53-0.78) and 0.58 (95% CI, 0.45-0.70), and specificity 0.72 (95% CI, 0.58-0.83) and 0.87 (95% CI, 0.75-0.95) for MRI and CBCT, respectively. Area under the curve was 0.74 (95% CI, 0.65-0.83) for MRI and 0.75 (95% CI, 0.66-0.84) for CBCT.

Conclusions: There was no significant difference in sensitivity or specificity between MRI and CBCT in detecting VRF, despite the early-stage development of MRI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10330038PMC
http://dx.doi.org/10.1016/j.joen.2023.03.011DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
16
mri cbct
16
mri
10
cbct
9
specificity mri
8
vertical root
8
cbct detecting
8
detecting vrf
8
inter-rater reliability
8
95%
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!