Purpose: Knowledge of the timing of cardiac valve opening and closing is important in cardiac physiology. The relationship between valve motion and electrocardiogram (ECG) is often assumed, however is not clearly defined. Here we investigate the accuracy of cardiac valve timing estimated using only the ECG, compared to Doppler echocardiography (DE) flow imaging as the gold standard.

Methods: DE was obtained in 37 patients with simultaneous ECG recording. ECG was digitally processed and identifiable features (QRS, T, P waves) were examined as potential reference points to determine opening and closure of aortic and mitral valves, as compared to DE outflow and inflow measurement. Timing offset of the cardiac valves opening and closure between ECG features and DE was measured from derivation set (n = 19). The obtained mean offset in combination with the ECG features model was then evaluated on a validation set (n = 18). Using the same approach, additional measurement was also done for the right sided valves.

Results: From the derivation set, we found a fixed offset of 22 ± 9 ms, 2 ± 13 ms, 90 ± 26 ms, and - 2 ± - 27 ms when comparing S to aortic valve opening, T to aortic valve closure, T to mitral valve opening, and R to mitral valve closure respectively. Application of this model to the validation set showed good estimation of aortic and mitral valve opening and closure timing value, with low model absolute error (median of the mean absolute error of the four events = 19 ms compared to the gold standard DE measurement). For the right-sided (tricuspid and pulmonic) valves in our patient set, there was considerably higher median of the mean absolute error of 42 ms for the model.

Conclusion: ECG features can be used to estimate aortic and mitral valve timings with good accuracy as compared to DE, allowing useful hemodynamic information to be derived from this easily available test.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13239-023-00664-4DOI Listing

Publication Analysis

Top Keywords

valve opening
20
opening closure
16
mitral valve
16
aortic valve
12
aortic mitral
12
ecg features
12
absolute error
12
valve
10
cardiac valve
8
derivation set
8

Similar Publications

Diagnostic value of selected fetal echocardiographic parameters in the prenatally suspected bicuspid aortic valve.

Echo Res Pract

January 2025

Echocardiography Medical Center, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, 100029, China.

Objective: To explore the diagnostic value of crucial parameters of echocardiography for fetal bicuspid aortic valve (BAV) and improve diagnostic accuracy.

Methods: Fetuses with a prenatal suspected diagnosis of BAV were followed, and confirmed and misdiagnosed cases were obtained. Prenatal echocardiography was reviewed and analyzed.

View Article and Find Full Text PDF

We report a 75-year-old female with a history of two heart operations: aortic valve replacement (St. Jude Medical 21 mm) at the age of 44 years for severe rheumatic aortic stenosis and mitral valve replacement (Carbomedics 29 mm) at the age of 51 years for rheumatic mitral regurgitation. Decades later, she presented with exertional dyspnea.

View Article and Find Full Text PDF

Optimizing multireagent assays often requires successive titration of individual components until the optimal combination of conditions is achieved. This process is time-consuming, laborious, and often expensive since parallelized experimentation requires bulk consumption of reagents. Microfluidics presents a solution through miniaturization of standard processes by reducing reaction volume, executing multiple parallel workflows, and enabling automation.

View Article and Find Full Text PDF

Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising -isopropylacrylamide (NIPAM), ,'-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane.

View Article and Find Full Text PDF

Unveiling the impact of pipe materials on water hammer in pressure pipelines: an experimental and numerical study.

Sci Rep

December 2024

Department of Mechanical Design, Faculty of Engineering, Helwan University, P.O. Box 11718, Mataria, Helmeiat-Elzaton, Cairo, Egypt.

Water hammer (WH) is a phenomenon characterized by the rapid opening or closing of valves or pumps in pipelines, resulting in a disruptive noise, intense vibrations, and potential damage to pipes, fittings, structures, and even human safety. While WH arresters are commonly employed to mitigate this issue in smaller plumbing systems, alternative solutions are required for larger applications like power plants. Researchers have proposed the utilization of pipe materials with a low modulus of elasticity in areas prone to WH events, as these materials possess the capability to absorb a significant portion of the resulting vibrations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!