A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of Long-term Performance of the GORE SYNECOR Intraperitoneal Biomaterial in the Treatment of Inguinal Hernias. | LitMetric

Background: The objective of this study was to analyze device safety and clinical outcomes of inguinal hernia repair with the GORE SYNECOR Intraperitoneal Biomaterial device, a hybrid composite mesh.

Methods: This retrospective case review analyzed device/procedure endpoints beyond 1 year in patients treated for inguinal hernia repair with the device. Three objectives were evaluated: procedural endpoint-incidence through 30 days of surgical site infection, surgical site occurrence (SSO), ileus, readmission, reoperation, and death; device endpoint-serious device incidence of mesh erosion, infection, excision/removal, exposure, migration, shrinkage, device-related bowel obstruction and fistula, and hernia recurrence through 12 months; and patient-reported outcomes of the bulge, physical symptoms, and pain.

Results: A total of 157 patients (mean age: 67±13 y) with 201 inguinal hernias (mean size: 5.1±5 cm 2 ) were included. Laparoscopic approach and bridging repair were performed in 99.4% of patients. All device location was preperitoneal. No procedure-related adverse events within 30 days were reported. No surgical site infection or SSO events or device-related hernia recurrence occurred through 12 months. Procedure-related serious adverse events occurred in 6 patients; 5 recurrent inguinal hernias (at 1 and 2 y) and 1 scrotal hematoma (at 6 mo). Through 24 months, no SSO events requiring procedural intervention occurred. Through 50 months, 6 (2.98%) patients had confirmed hernia recurrence and 4 (1.99%) patients had hernia reoperation. The patient-reported outcome for pain was reported by 7.9% (10/126) of patients who completed the questionnaire.

Conclusions: In this study, inguinal hernia repair with the hybrid composite mesh was successful in most patients and the rate of recurrence was low, further supporting the long-term safety and device performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10234318PMC
http://dx.doi.org/10.1097/SLE.0000000000001166DOI Listing

Publication Analysis

Top Keywords

inguinal hernias
12
inguinal hernia
12
hernia repair
12
surgical site
12
hernia recurrence
12
gore synecor
8
synecor intraperitoneal
8
intraperitoneal biomaterial
8
hybrid composite
8
patients
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!