AI Article Synopsis

  • The study focuses on measuring nitrous oxide isotopocules using isotope ratio mass spectrometry (IRMS) and addresses the need for a software tool to correct for ion source "scrambling."
  • A new Python package named pyisotopomer was developed to help researchers obtain specific coefficients for this correction and accurately analyze N2O samples.
  • Results indicate that calibration with reference materials is crucial and that IRMS scrambling can change over time, requiring regular recalibration and collaboration between laboratories for accurate measurements.

Article Abstract

Rationale: Obtaining nitrous oxide isotopocule measurements with isotope ratio mass spectrometry (IRMS) involves analyzing the ion current ratios of the nitrous oxide parent ion (N O ) as well as those of the NO fragment ion. The data analysis requires correcting for "scrambling" in the ion source, whereby the NO fragment ion obtains the outer N atom from the N O molecule. While descriptions exist for this correction, and interlaboratory intercalibration efforts have been made, there has yet to be published a package of code for implementing isotopomer calibrations.

Methods: We developed a user-friendly Python package (pyisotopomer) to determine two coefficients (γ and κ) that describe scrambling in the IRMS ion source, and then used this calibration to obtain intramolecular isotope deltas in N O samples.

Results: With two appropriate reference materials, γ and κ can be determined robustly and accurately for a given IRMS system. An additional third reference material is needed to define the zero-point of the delta scale. We show that IRMS scrambling behavior can vary with time, necessitating regular calibrations. Finally, we present an intercalibration between two IRMS laboratories, using pyisotopomer to calculate γ and κ, and to obtain intramolecular N O isotope deltas in lake water unknowns.

Conclusions: Given these considerations, we discuss how to use pyisotopomer to obtain high-quality N O isotopocule data from IRMS systems, including the use of appropriate reference materials and frequency of calibration.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.9513DOI Listing

Publication Analysis

Top Keywords

intramolecular isotope
12
nitrous oxide
12
python package
8
isotope ratio
8
fragment ion
8
ion source
8
isotope deltas
8
appropriate reference
8
reference materials
8
irms
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!