Background: The joint position sense (JPS) is an element of proprioception and defined as an individual's ability to recognize joint position in space. The JPS is assessed by measuring the acuity of reproducing a predetermined target angle. The quality of psychometric properties of knee JPS tests after anterior cruciate ligament reconstruction (ACLR) is uncertain.

Purpose/hypothesis: The purpose of this study was to evaluate the test-retest reliability of a passive knee JPS test in patients who underwent ACLR. We hypothesized that the passive JPS test would produce reliable absolute error, constant error, and variable error estimates after ACLR.

Study Design: Descriptive laboratory study.

Methods: Nineteen male participants (mean age, 26.3 ± 4.4 years) who had undergone unilateral ACLR within the previous 12 months completed 2 sessions of bilateral passive knee JPS evaluation. JPS testing was conducted in both the flexion (starting angle, 0°) and the extension (starting angle, 90°) directions in the sitting position. The absolute error, constant error, and variable error of the JPS test in both directions were calculated at 2 target angles (30° and 60° of flexion) by using the angle reproduction method for the ipsilateral knee. The standard error of measurement (SEM), smallest real difference (SRD), and intraclass correlation coefficients (ICCs) with 95% Cis were calculated.

Results: ICCs were higher for the JPS constant error (operated and nonoperated knee, 0.43-0.86 and 0.32-0.91, respectively) compared with the absolute error (0.18-0.59 and 0.09-0.86, respectively) and the variable error (0.07-0.63 and 0.09-0.73, respectively). The constant error of the 90°-60° extension test showed moderate to excellent reliability for the operated knee (ICC, 0.86 [95% CI, 0.64-0.94]; SEM, 1.63°; SRD, 4.53°), and good to excellent reliability for the nonoperated knee (ICC, 0.91 [95% CI, 0.76-0.96]; SEM, 1.53°; SRD, 4.24°).

Conclusion: The test-retest reliability of the passive knee JPS tests after ACLR varied depending on the test angle, direction, and outcome measure (absolute error, constant error, or variable error). The constant error appeared to be a more reliable outcome measure than the absolute error and the variable error, mainly during the 90°-60° extension test.

Clinical Relevance: As constant errors have been found reliable during the 90°-60° extension test, investigating these errors-in addition to absolute and variable errors-to reflect bias in passive JPS scores after ACLR is warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10034299PMC
http://dx.doi.org/10.1177/23259671231157351DOI Listing

Publication Analysis

Top Keywords

constant error
24
absolute error
20
variable error
20
error
17
knee jps
16
error constant
16
error variable
16
test-retest reliability
12
reliability passive
12
joint position
12

Similar Publications

Purpose: This study compared %BFUS to %BF4C in young adult athletes.

Methods: University club sport athletes (86 women, 138 men) from a variety of teams participated. ADP, DXA, and bioimpedance spectroscopy were used to measure body volume, bone mineral content, and total body water, respectively, for the 4C model.

View Article and Find Full Text PDF

This study aims to enhance positron emission tomography (PET) imaging systems by developing a continuous depth-of-interaction (DOI) measurement technique using a single-ended readout. Our primary focus is on reducing the number of readout channels in the scintillation detectors while maintaining accurate DOI estimations, using a high-pass filter-based signal multiplexing technique combined with artificial neural networks (ANNs). Approach: Instead of reading out all 64 signals from an 8×8 silicon photomultiplier array for DOI estimation, the proposed method technique reduces the signals into just four channels by applying high-pass filters with different time constants.

View Article and Find Full Text PDF

Understanding cytokine-related therapeutic protein-drug interactions (TP-DI) is crucial for effective medication management in conditions characterized by elevated inflammatory responses. Recent FDA and ICH guidelines highlight a systematic, risk-based approach for evaluating these interactions, emphasizing the need for a thorough mechanistic understanding of TP-DIs. This study integrates the physiologically based pharmacokinetic (PBPK) model for TP (specifically interleukin-6, IL-6) with small-molecule drug PBPK models to elucidate cytokine-related TP-DI mechanistically.

View Article and Find Full Text PDF

Our commentary suggests that different materialities (fragile, enduring, and mixed) may influence cognitive evolution. Building on Stibbard-Hawkes, we propose that predictive brains minimise errors and seek information, actively structuring environments for epistemic benefits. This perspective complements Stibbard-Hawkes' view.

View Article and Find Full Text PDF

Introduction: The linear and continuous increase in power output (PO) during ramp incremental (RI) exercise causes a distinct V̇O2/PO relationship compared to constant work rate (CWR) exercise. Current methods enabling a translation of ramp-derived PO to CWR PO assume a linear development of the CWR V̇O2/PO relationship in the heavy-intensity domain. This study aimed to model the RI versus CWR V̇O2/PO relationship to investigate whether the loss of mechanical efficiency above GET develops linearly.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!