The mutual restriction between angle detection accuracy and spatial resolution of image will restrict the detection of long distance by multi-vision system. One higher resolution image of a multi-vision system can be used to improve the resolution of the images of each camera. In present paper, a new fusion method with the help of one higher resolution image is proposed and analytically studied. As an example, an image fusion for the images captured by the combining optical system of camera arrays and the synthetic aperture is studied. Both of the simulation and experiment shows that the proposed method is simple and accuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10031340PMC
http://dx.doi.org/10.1016/j.heliyon.2023.e14433DOI Listing

Publication Analysis

Top Keywords

resolution image
16
multi-vision system
12
image fusion
8
long distance
8
higher resolution
8
image
6
resolution
5
fusion multi-vision
4
system
4
system high
4

Similar Publications

With the rapid development of nanotechnology, nanoultrasonography has emerged as a promising medical imaging technique that demonstrates significant potential in the diagnosis and treatment of gastrointestinal (GI) diseases. This review discusses the applications of nanoultrasonography in the gastrointestinal field, including improvements in imaging resolution, diagnostic accuracy, latest research findings, and prospects for clinical application. By analyzing existing literature, we explore the role of nanoultrasonography in enhancing imaging resolution, enabling targeted drug delivery, and improving therapeutic outcomes, thereby providing a reference for future research directions.

View Article and Find Full Text PDF

Background: Computed tomography (CT) is the gold standard imaging modality for the assessment of 3D bony morphology but incurs the cost of ionizing radiation exposure. High-resolution 3D magnetic resonance imaging (MRI) with CT-like bone contrast (CLBC) may provide an alternative to CT in allowing complete evaluation of both bony and soft tissue structures with a single MRI examination.

Purpose: To review the technical aspects of an optimized stack-of-stars 3D gradient recalled echo pulse sequence method (3D-Bone) in generating 3D MR images with CLBC, and to present a pictorial review of the utility of 3D-Bone in the clinical assessment of common musculoskeletal conditions.

View Article and Find Full Text PDF

Centimeter-Sized CsPbBr Single-Crystal Films for Energy-Resolved Radiation Detection.

ACS Appl Mater Interfaces

January 2025

Beijing Key Laboratory of Construction-Tailorable Advanced Functional Materials and Green Applications Experimental Center of Advanced Materials, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China.

Metal halide perovskites (MHPs) are promising materials for radiation detection. Compared with polycrystalline films, single crystals (SCs) have lower defect density, higher carrier mobility, and lifetime. However, the direct synthesis of MHP SCs for large-area flat panel imaging detectors remains challenging.

View Article and Find Full Text PDF

Purpose: MR-based FID navigators (FIDnavs) do not require gradient pulses and are attractive for prospective motion correction (PMC) due to short acquisition times and high sampling rates. However, accuracy and precision are limited and depend on a separate calibration measurement. Besides FIDnavs, stationary NMR field probes are also capable of measuring local, motion-induced field changes.

View Article and Find Full Text PDF

The pulmonary vasculature plays a pivotal role in the development and progress of chronic lung diseases. Due to limitations of conventional two-dimensional histological methods, the complexity and the detailed anatomy of the lung blood circulation might be overlooked. In this study, we demonstrate the practical use of optical serial block face imaging (SBFI), ex vivo microcomputed tomography (micro-CT), and nondestructive optical tomography for visualization and quantification of the pulmonary circulation's 3D architecture from macro- to micro-structural levels in murine lung samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!