Objective: This study evaluated the stress distribution and displacement on impacted maxillary canines and their adjacent teeth of orthodontic forced eruption using Ballista and Kilroy springs by finite element model (FEM) analysis.

Methods: Two different FEMs applying the same force level on an impacted canine tooth (Model 1: Ballista spring, Model 2: Kilroy spring) were conducted using FEM analysis and the principal stresses, von Mises stresses, and displacements were evaluated.

Results: Von Mises values at the cusp tip of impacted canines were measured as 0.009896 N/mm² in the Ballista model and 0.015334 N/mm² in the Kilroy model. The highest value was measured in the buccal apex of the first premolar in both spring designs. The extrusion was observed in Ballista, and intrusion was observed in the Kilroy model at the apex of the first premolar. The Ballista model showed the highest value (0.003642 N/mm²) at the buccal tip of the first premolar, while in the Kilroy model, the highest measurement (0.002989 N/mm²) was shown at the incisal edge of the lateral tooth.

Conclusion: Von Mises stress values were higher in the Kilroy model at the cusp tip and apical part of the impacted tooth than that in the Ballista model. The highest von Mises stress values were concentrated on the buccal root apex of the first premolar in both models. Although the amount of force applied by the springs was the same, the stress values were different depending on the spring design.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10140656PMC
http://dx.doi.org/10.4274/TurkJOrthod.2022.2022.10DOI Listing

Publication Analysis

Top Keywords

von mises
16
kilroy model
16
model highest
16
ballista model
12
apex premolar
12
stress values
12
model
11
ballista kilroy
8
kilroy springs
8
impacted canines
8

Similar Publications

Introduction And Aims: Implantation of the posterior maxilla with insufficient bone height faces challenges. Studies have shown that the use of ultrashort implants can avoid additional damage. This finite element analysis study aimed to evaluate the impacts of different lengths of ultrashort implants and three surgical approaches on stress, strain, and displacement in the posterior maxilla with varying bone heights.

View Article and Find Full Text PDF

Purpose: We aimed to analyze the influence of different designs (inlay, onlay, and crown) on stress distribution and crack propagation in an endodontically treated cracked premolar.

Methods: Three-dimensional (3D) finite element analysis (FEA) was employed to model an endodontically treated cracked premolar with three different restorations (inlay, onlay, and crown). Six types of loadings (vertical loading of 600 N; hot thermal-600 N vertical coupling loading; cold thermal-600 N vertical coupling loading; oblique loading of 200 N; hot thermal-200 N oblique coupling loading; cold thermal-200 N oblique coupling loading) were applied to simulate the hot and cold food/beverages intake.

View Article and Find Full Text PDF

Effect of different restorative design and materials on stress distribution in cracked teeth: a finite element analysis study.

BMC Oral Health

January 2025

Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.

Objectives: To compare the stress distribution and crack propagation in cracked mandibular first molar restored with onlay, overlay, and two types of occlusal veneers using two different CAD/CAM materials by Finite Element Analysis (FEA).

Materials And Methods: A mandibular first molar was digitized using a micro CT scanning system in 2023. Three-dimensional dynamic scan data were transformed, and a 3D model of a cracked tooth was generated.

View Article and Find Full Text PDF

In this study, polysulfone/polyvinylpyrrolidone (PSf/PVP, 20 wt%/5 wt%)-based ultrafiltration (UF) membranes reinforced with different ratios (0.5 and 1 wt%) of cellulose nanocrystals (CNCs) and cellulose nanofibres (CNFs) were prepared by the phase inversion method. The effect of CNC, CNF, and CNC-CNF reinforcement on the morphology, roughness, crystallinity, porosity, average pore size, mechanical properties, and filtration performance of PSf/PVP-based membrane was investigated.

View Article and Find Full Text PDF

The Amount of Orthodontic Force Reaching the Dental Pulp and Neuro-Vascular Bundle During Orthodontic Movements in the Intact Periodontium.

Medicina (Kaunas)

December 2024

Department of Cariology, Endodontics and Oral Pathology, School of Dental Medicine, University of Medicine and Pharmacy Iuliu Hatieganu, Str. Motilor 33, 400001 Cluj-Napoca, Romania.

: Most orthodontic forces are absorbed-dissipated before reaching the dental pulp and its neuro-vascular bundle (NVB); however, no data are available about their amounts. The objective of this study was to assess the amount of orthodontic force that reaches the dental pulp and its NVB during orthodontic movements in a healthy periodontium. : This study involved the second lower premolars of nine patients and 180 numerical simulations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!