Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To compare the postoperative visual outcomes and quality of vision obtained with 2 types of diffractive trifocal intraocular lenses (IOLs) in patients with highly myopic cataracts.
Design: Prospective, multicenter, randomized controlled trial.
Methods: Patients with high-myopic cataracts were randomized to binocular implantation of either the TFNT00 (n = 27) or the 839 MP (n = 28) trifocal IOLs at 3 surgery centers in China and were followed up for 1 year. Postoperative uncorrected distance, uncorrected intermediate, and uncorrected near visual acuity, and best-corrected distance visual acuity were measured. The defocus curve, high-order aberrations, modulation transfer function curve, Strehl ratio, and reading ability were compared between both groups. The functional vision and incidence of photic phenomena were surveyed using questionnaires.
Results: Visual acuity at all ranges of vision was significantly improved in both groups. The TFNT00 group showed superior uncorrected intermediate visual acuity to that in the 839 MP group (P = .013). Reading ability at 40 and 60 cm was similar in both groups (P ≥ .05), whereas the preferred reading distances for near and intermediate were significantly different. The TFNT00 group had a significantly higher mean Visual Function Index 14 score, lower incidence of photic phenomena, and less posterior capsular opacity than the 839 MP group.
Conclusion: Bilateral implantation of both types of trifocal IOLs in patients with high-myopic cataracts provided good whole-course visual restoration, although recognition of fine Chinese characters remained impeded. As compared with 839 MP IOL, TFNT00 IOL resulted in greater patient satisfaction in intermediate activities, with a lower photic phenomena incidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ajo.2023.03.015 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!